Over the last 4 years, IMRT, IGRT, SBRT: Advances in the Treatment Planning and Delivery of Radiotherapy has become a standard reference in the field. During this time, however, significant progress in high-precision technologies for the planning and delivery of radiotherapy in cancer treatment has called for a second edition to include these new developments. Thoroughly updated and extended, this new edition offers a comprehensive guide and overview of these new technologies and the many clinical treatment programs that bring them into practical use. Advances in intensity-modulated radiotherapy (IMRT), and 4D and adaptive treatment planning are clearly presented. Target localization and image-guided radiotherapy (IGRT) systems are comprehensively reviewed as well. Clinical tutorials illustrate target definitions for the major cancer sites, and useful techniques for organ motion management are described and compared. There are also several chapters that explore the technical basis and latest clinical experience with stereotactic body radiotherapy (SBRT) and summarize practical treatment recommendations. Furthermore, the significant and increasing contributions of proton therapy to cancer care are also highlighted, alongside the practical allocation of all these new technologies from an economic perspective. As a highlight of this volume, a number of images can be viewed online in time-elapse videos for greater clarity and more dynamic visualizationWritten by leading authorities in the field, this comprehensive volume brings clinical and technical practitioners of radiotherapy fully up to date with the key developments in equipment, technologies and treatment guidelines.

Frequently asked questions

How do I cancel my subscription?
Simply head over to the account section in settings and click on “Cancel Subscription” - it’s as simple as that. After you cancel, your membership will stay active for the remainder of the time you’ve paid for. Learn more here.
Can/how do I download books?
At the moment all of our mobile-responsive ePub books are available to download via the app. Most of our PDFs are also available to download and we're working on making the final remaining ones downloadable now. Learn more here.
What is the difference between the pricing plans?
Both plans give you full access to the library and all of Perlego’s features. The only differences are the price and subscription period: With the annual plan you’ll save around 30% compared to 12 months on the monthly plan.
What is Perlego?
We are an online textbook subscription service, where you can get access to an entire online library for less than the price of a single book per month. With over 1 million books across 1000+ topics, we’ve got you covered! Learn more here.
Do you support text-to-speech?
Look out for the read-aloud symbol on your next book to see if you can listen to it. The read-aloud tool reads text aloud for you, highlighting the text as it is being read. You can pause it, speed it up and slow it down. Learn more here.
Is IMRT, IGRT, SBRT an online PDF/ePUB?
Yes, you can access IMRT, IGRT, SBRT by J. L. Meyer in PDF and/or ePUB format, as well as other popular books in Médecine & Radiologie, radiothérapie et médecine nucléaire. We have over one million books available in our catalogue for you to explore.

Information

Integrating IMRT and IGRT into Treatment Delivery
Meyer JL (ed): IMRT, IGRT, SBRT - Advances in the Treatment Planning and Delivery of
Radiotherapy, ed 2, rev. and ext. Front Radiat Ther Oncol. Basel, Karger, 2011, vol. 43, pp 132–164



______________________

Technologies of Image Guidance and the Development of Advanced Linear Accelerator Systems for Radiotherapy

Vincent W.C. Wuc • Maria Y.Y. Lawc • Josh Star-Lackb • Fion W.K. Cheungc,d • C. Clifton Ling a-c
aDepartment of Medical Physics, Memorial Sloan-Kettering Cancer Center, New York, N.Y., bVarian Medical Systems, Palo Alto, Calif., USA; cDepartment of Health Technology and Informatics, Hong Kong Polytechnic University, and d Department of Clinical Oncology, Queen Elizabeth Hospital, Hong Kong, China




______________________

Abstract

As advanced radiotherapy approaches for targeting the tumor and sparing the normal tissues have been developed, the image guidance of therapy has become essential to directing and confirming treatment accuracy. To approach these goals, image guidance devices now include kV on-board imagers, kV/MV cone-beam CT systems, CT-on-rails, and mobile and in-room radiographic/fluoroscopic systems. Nonionizing sources, such as ultrasound and optical systems, and electromagnetic devices have been introduced to monitor or track the patient and/or tumor positions during treatment. In addition, devices have been designed specifically for monitoring and/or controlling respiratory motion. Optimally, image-guided radiation therapy systems should possess 3 essential elements: (1) 3D imaging of soft tissues and tumors, (2) efficient acquisition and comparison of the 3D images, and (3) an efficacious process for clinically meaningful intervention. Understanding and using these tools effectively is central to current radiotherapy practice. The implementation and integration of these devices continue to carry practical challenges, which emphasize the need for further development of the technologies and their clinical applications.
Copyright © 2011 S. Karger AG, Basel
The evolution of technologies for image-guided radiation therapy (IGRT) has been rapid over the last 2 decades. During the 1980s, computer control of the linear accelerator (linac) was implemented, which was an important step for subsequent developments. Subsequently, electronic portal imaging devices (fig. 1) were introduced, enabling digital portal imaging - the first step in modern IGRT. More recently, imaging devices capable of generating 3D images of soft tissues have been incorporated into radiation treatment devices, ushering in a new era of IGRT [1]. Of course, image guidance (IG) for radiation oncology has broader meanings [2], and perhaps the current process should really be called IG during radiation treatment delivery. In the past decade, we have seen a plethora of other IG devices such as kV on-board imagers, kV/MV cone-beam CT (CBCT) systems, CT-on-rails, and mobile and in-room radiographic/fluoroscopic systems. Nonionizing sources, such as ultrasound and optical systems, and electromagnetic devices, were introduced to set up, monitor, or track the patient and/or tumor positions during treatment. In addition, devices were designed specifically for monitoring and/or controlling respiratory motion [e.g. the Varian Real-Time Position Management (RPM) System; fig. 2].
Fig. 1. Linear accelerator equipped with electronic portal imaging device.
Img
Since many of these systems serve different functions, well-equipped facilities may have a multitude of such devices, each serving a specific function but not interfacing well with the other devices, or even with the linac. The delivery process may be much less seamlessly integrated. In addition, each new device arrives with a dedicated computer, requiring its own interfaces, networks and workarounds for practical implementation. As shown in figure 3, the control area of a radiation therapy machine can become crowded with computer monitors, increasing the burden and complexities confronted by the radiotherapists and staff.
Fig. 2. RPM system by Varian Medical Systems: infrared reflector (A), infrared camera (B).
Img
Fig. 3. The display workstations in the control room of a linear accelerator. Each workstation displays one function during treatment delivery.
Img

Technologies to Meet the Goals of Image-Guided Radiation Therapy

The goal of IGRT is to reduce treatment uncertainties, which can occur between fractions (interfraction) or during the treatment (intrafraction). Imaging can provide guidance of treatment in several ways. To address interfractional errors, repositioning or replanning can be performed. To reduce intrafractional uncertainties, imaging during treatment can monitor the positions of internal structures and provide the basis for correction. In developing technologies for IGRT, the key issues are whether the imaging systems and processes are efficient and accurate enough. Ling et al. [1] and Greco and Ling [2], suggested that an ideal IGRT system should possess 3 essential elements: (1) 3D imaging of soft tissues and tumors, (2) efficient acquisition and comparison of the 3D images, and (3) an efficacious process for clinically meaningful intervention.
Huntzinger et al. [3] described 4 technical criteria for the assessment of successful technologies for image-guided stereotactic radiosurgery: (1) a treatment planning system that generates dose distributions, with rapid dose fall-off from the tumor in all 3 dimensions, through the use of beams converging from many directions; (2) imaging systems with submillimeter accuracy that can account for target motion; (3) a high-resolution, accurate and efficient delivery method; and (4) a system that is fully integrated to enable perfect geometric alignment between imaging, planning and targeting of tumor volumes.
Others have commented on the cost-benefit analysis of the new technologies [1, 4, 5]. In terms of economics, there is significant cost in initiating and implementing IGRT. Other than the investment in the in-room imaging and motion control facilities, human resources and machine time are also important considerations. The increased machine time per patient means an overall reduced throughput of patients per machine. Questions can be raised if the increased cost is not balanced by the benefits that IGRT will bring.
If our goal is to improve clinical outcomes in a cost-effective manner, then a major challenge becomes how to best apply the various technologies that have been developed. The addition of new, emerging technologies will only intensify this concern. For simplicity, perhaps we can consider 2 steps in meeting this challenge. The first is a vetting process in terms of what individual devices will be used, when to use them and how to use them. The second is how best to integrate the selected devices, systems and processes with linac-based radiation delivery in a coordinated approach.

Validation and Vetting of Image-Guided Radiation Therapy Devices

Ideally, the evaluation of the clinical efficacy of a technology should involve the quantification of its benefits in objective clinical outcome measures. To be reliable, this requires comparative phase III clinical trials with sufficient follow-up. There are many obstacles for such trials. The time required for their planning, approval and organization, reticence to submit cases to the randomization process, and clinical imperatives to individualize treatments based on the specifics of medical cases lead to difficulties in patient accrual and render such trials highly impractical. Even if conducted, due to the lengthy nature of clinical trials and the rapid evolution of the technologies, the conclusions may be outdated and irrelevant before they are even derived [4, 5]. A recent perusal of a database on IGRT publications revealed little data reporting objective clinical outcomes.
In the absence of clinical outcome data, we are left with surrogates for documenting clinical advances. This approach retreats to the dogma that reductions of setup uncertainties and minimizations of organ motion effects, carefully measured, lead to outcome improvements. Even with these data, there will be many challenges in the vetting process of devices. This is partly because there are many competing and an ever increasing variety of technologies and products, and partly because the standards and metrics for their evaluation are still evolving. Some of the metrics may be easy to define, such as spatial accuracy, acquisition time, invasiveness and soft tissue contrast/discrimination. Others are more nebulous, with some being device-specific and/or institution-specific in terms of the usefulness of an approach. The surrogates and metrics used in various studies on IGRT will be described in more detail in later sections.
Other factors in the evaluation of a device or system are its applicability and ease of use. In general, devices that can be applied to many major disease sites will be more widely accepted. As to ease of use, Joel Tepper recently said ‘the less direct physician physical intervention, the more likely newer techniques will be accepted’, highlighting the importance of physicians’ acceptance of their involvement in the workflow of IGRT. This precept could be broadened to ‘the less direct user (clinicians, physicists and radiotherapists) physical intervention, the more likely newer techniques will be accepted’.
The ease of use of a device also depends on how well it is integrated into the treatment pro...

Table of contents