Mine Ventilation and Air Conditioning
eBook - ePub

Mine Ventilation and Air Conditioning

Howard L. Hartman, Jan M. Mutmansky, Raja V. Ramani, Y. J. Wang

Condividi libro
  1. English
  2. ePUB (disponibile sull'app)
  3. Disponibile su iOS e Android
eBook - ePub

Mine Ventilation and Air Conditioning

Howard L. Hartman, Jan M. Mutmansky, Raja V. Ramani, Y. J. Wang

Dettagli del libro
Anteprima del libro
Indice dei contenuti
Citazioni

Informazioni sul libro

This revised edition presents an engineering design approach to ventilation and air conditioning as part of the comprehensive environmental control of the mine atmosphere. It provides an in-depth look, for practitioners who design and operate mines, into the health and safety aspects of environmental conditions in the underground workplace.

Domande frequenti

Come faccio ad annullare l'abbonamento?
È semplicissimo: basta accedere alla sezione Account nelle Impostazioni e cliccare su "Annulla abbonamento". Dopo la cancellazione, l'abbonamento rimarrà attivo per il periodo rimanente già pagato. Per maggiori informazioni, clicca qui
È possibile scaricare libri? Se sì, come?
Al momento è possibile scaricare tramite l'app tutti i nostri libri ePub mobile-friendly. Anche la maggior parte dei nostri PDF è scaricabile e stiamo lavorando per rendere disponibile quanto prima il download di tutti gli altri file. Per maggiori informazioni, clicca qui
Che differenza c'è tra i piani?
Entrambi i piani ti danno accesso illimitato alla libreria e a tutte le funzionalità di Perlego. Le uniche differenze sono il prezzo e il periodo di abbonamento: con il piano annuale risparmierai circa il 30% rispetto a 12 rate con quello mensile.
Cos'è Perlego?
Perlego è un servizio di abbonamento a testi accademici, che ti permette di accedere a un'intera libreria online a un prezzo inferiore rispetto a quello che pagheresti per acquistare un singolo libro al mese. Con oltre 1 milione di testi suddivisi in più di 1.000 categorie, troverai sicuramente ciò che fa per te! Per maggiori informazioni, clicca qui.
Perlego supporta la sintesi vocale?
Cerca l'icona Sintesi vocale nel prossimo libro che leggerai per verificare se è possibile riprodurre l'audio. Questo strumento permette di leggere il testo a voce alta, evidenziandolo man mano che la lettura procede. Puoi aumentare o diminuire la velocità della sintesi vocale, oppure sospendere la riproduzione. Per maggiori informazioni, clicca qui.
Mine Ventilation and Air Conditioning è disponibile online in formato PDF/ePub?
Sì, puoi accedere a Mine Ventilation and Air Conditioning di Howard L. Hartman, Jan M. Mutmansky, Raja V. Ramani, Y. J. Wang in formato PDF e/o ePub, così come ad altri libri molto apprezzati nelle sezioni relative a Tecnologia e ingegneria e Salute e sicurezza sul lavoro. Scopri oltre 1 milione di libri disponibili nel nostro catalogo.

Informazioni

Anno
2012
ISBN
9781118591543

PART I

INTRODUCTION

CHAPTER 1

Environmental Control of the Mine Atmosphere

1.1 PURPOSE AND IMPORTANCE

In the vacuum of outer space, human astronauts rely on the artificial atmosphere of a spacecraft for their life support system. While differing in locale and mission, human miners are no less dependent on an artificial atmosphere to sustain them in underground mines where the air may be stagnant and contaminated.
It is evident that both miners and astronauts confront a hostile environment, and that both groups must depend on a ventilation–air conditioning system to supply them adequate air for breathing.
Under even normal circumstances, excavation in the earth—like exploration in space—can be fraught with a variety of environmental problems and hazards. While ground support is an obvious and compelling need, the most vital aspect of the mine environment to control is the atmosphere of the workplace.
To the mining engineer, ventilation is the most versatile atmospheric control tool. It is the process relied on to accomplish most environmental control underground. Mine ventilation is essentially the application of the principles of fluid dynamics to the flow of air in mine openings. As the primary means of quantity control, ventilation is responsible for the circulation of air, in both amount and direction, throughout the mine. It is one of the constituent processes of total mine air conditioning, the simultaneous control within prescribed limits of the quality, quantity, and temperature-humidity of mine air (Anon., 1993).
Increasingly, in underground mining, environmental objectives require that we condition air to meet quality and temperature–humidity standards as well as quantity criteria. In recent years, these standards have been raised substantially. Although threshold limits are based on human safety and tolerance, increasing concern is being expressed for standards of human comfort as well. The provision of a comfortable work environment is both cost-effective and humanitarian. Worker productivity and job satisfaction correlate closely with environmental quality. Further, excessive accident rates and workers’ compensation rates are a consequence of unsatisfactory as well as unsafe environmental conditions. No mining company today can afford to be lax in its environmental and air-control practices.

Historical Perspectives and Natural Constraints

The importance of mine ventilation and air conditioning has not just newly been recognized. From the onset of underground mining in Paleolithic times, perhaps as early as 40,000 BCE (B.C.) (Gregory, 1980, p. 50), miners confronted oxygen deficiency, toxic gases, harmful dusts, and debilitating heat. As miners became more skilled, by the first millennium BCE, they learned to course the air through multiple openings or circuits to provide fresh air to the working face (Lacy and Lacy, 1992, p. 5) and to use fire-induced air currents (McPherson, 1993, p. 2).
By the Middle Ages, mine ventilation enjoyed the status of a mining art. In the most celebrated early mining treatise, Georgius Agricola (1556, p. 200), a respected German scholar and scientist, decried the evils of the foul atmospheric environments in which miners had to work and pictured their still-primitive efforts to combat these conditions:
I will now speak of ventilating machines. If a shaft is very deep and no tunnel reaches to it, or no drift from another shaft connects with it, or when a tunnel is of great length and no shaft reaches to it, then the air does not replenish itself. In such a case it weighs heavily on the miners, causing them to breathe with difficulty, and sometimes they are even suffocated, and burning lamps are also extinguished. There is, therefore, a necessity for machines which the Greeks call
and the Latins, spiritales—although they do not give forth any sound—which enable the miners to breathe easily and carry on their work.*
Figures 1.1a-c, taken from Agricola’s book, portray some of these early “ventilating machines.” A contemporary history of mine ventilation is presented by McPherson (1993, pp. 1-7).
FIGURE 1.1 Mine ventilation machines of Agricola’s day: (a) deflectors; (b) bellows; (c) fans.
[Parts (a)-(c) from Agricola, 1556. By permission from Dover Publications, Inc., copyright 1950.]
Technology has vastly improved mine ventilation, although environmental challenges underground still abound. Depth, the most serious natural constraint, sets the ultimate limit, specifically through rock pressure and rock temperature. Not only do rock pressures rise inexorably with depth but temperatures do also, with subsequent deterioration of the atmosphere. According to Spalding (1949, p. 238):
Of all the factors which affect mining operations, high rock temperature is the one most often likely to limit the depth to which those operations can be extended. The science of ventilation is therefore rapidly becoming the most important branch of deep mining.
At great depths, ventilation requirements and costs eventually climb to unsustainable levels. To preserve mine atmospheric quality under these intense heat conditions, ventilation at great depths must be supplemented by air conditioning.
Although heat generated by depth imposes the ultimate limit, the mine and its atmosphere have other detrimental conditions to withstand. These consist usually of airborne contaminants such as gases and dusts. As mines expand in size, complexity, manpower, and mechanization, demands on the ventilation–air conditioning system to maintain more stringent standards of environmental quality likewise rise. Fortunately, advances in mining science and technology tend to keep pace with worsening hazards underground. The struggle, however, is a continuous one reflected in both human safety and operating costs.

1.2 CONTROL PROCESSES

Lest confusion arise in the mind of the reader, it is well to clarify some of the terms related to environmental control of the mine atmosphere. Used alone, in mining parlance, air conditioning denotes only the function of temperature–humidity control, generally cooling or heating. To signify total mine air conditioning and all the functions of environmental control i...

Indice dei contenuti