
eBook - ePub
Stainless Steel 2000
Thermochemical Surface Engineering of Stainless Steel
- 448 pages
- English
- ePUB (mobile friendly)
- Available on iOS & Android
eBook - ePub
About this book
Austenitic stainless steels lend themselves to a wide range of applications. However, they normally stiffer from poor wear resistance and do not respond well to traditional surface treatments. This volume. the fruit of a current status seminar, reflects the enormous strides which have been made in the last few years in the study of the expanded austenite phase (also called the S phase) and the development of new surface treatment techniques. As well as the papers presented at the seminar, the book contains selection from related papers and a comprehensive bibliography of the literature on the subject from 1979 to 2000.
Frequently asked questions
Yes, you can cancel anytime from the Subscription tab in your account settings on the Perlego website. Your subscription will stay active until the end of your current billing period. Learn how to cancel your subscription.
No, books cannot be downloaded as external files, such as PDFs, for use outside of Perlego. However, you can download books within the Perlego app for offline reading on mobile or tablet. Learn more here.
Perlego offers two plans: Essential and Complete
- Essential is ideal for learners and professionals who enjoy exploring a wide range of subjects. Access the Essential Library with 800,000+ trusted titles and best-sellers across business, personal growth, and the humanities. Includes unlimited reading time and Standard Read Aloud voice.
- Complete: Perfect for advanced learners and researchers needing full, unrestricted access. Unlock 1.4M+ books across hundreds of subjects, including academic and specialized titles. The Complete Plan also includes advanced features like Premium Read Aloud and Research Assistant.
We are an online textbook subscription service, where you can get access to an entire online library for less than the price of a single book per month. With over 1 million books across 1000+ topics, we’ve got you covered! Learn more here.
Look out for the read-aloud symbol on your next book to see if you can listen to it. The read-aloud tool reads text aloud for you, highlighting the text as it is being read. You can pause it, speed it up and slow it down. Learn more here.
Yes! You can use the Perlego app on both iOS or Android devices to read anytime, anywhere — even offline. Perfect for commutes or when you’re on the go.
Please note we cannot support devices running on iOS 13 and Android 7 or earlier. Learn more about using the app.
Please note we cannot support devices running on iOS 13 and Android 7 or earlier. Learn more about using the app.
Yes, you can access Stainless Steel 2000 by Tom Bell,Katsuya Akamatsu in PDF and/or ePUB format, as well as other popular books in Technology & Engineering & Mining Engineering. We have over one million books available in our catalogue for you to explore.
Information
Towards Quantifying the Composition of Expanded Austenite
M.P. FEWELLa*, P. GARLICKb, J.M. PRIESTa†, P.T. BURKEc, N. DYTLEWSKIc, K.E. PRINCEc, K.T. SHORTc, R.G. ELLIMANd, H. TIMMERSd,e, T.D.M. Weijersd,e and B. GONGf
aPhysics and Electronics, University of New England, Armidale NSW 2351, Australia
bElectron Microscope Unit, University of New England, Armidale, NSW 2351, Australia
cAustralian Nuclear Science and Technology Organisation, Menai, NSW2234, Australia
dDepartment of Electronic Materials Engineering, Australian National University, Canberra, ACT 0200, Australia
eDepartment of Nuclear Physics, Australian National University, Canberra, ACT 0200, Australia
fSurface Science and Technology, School of Chemistry, University of New South Wales, Sydney, NSW 2052, Australia
This paper is dedicated to the memory of Trevor Richard Ophel, Professor of Nuclear Physics in the Australian National University, who died suddenly on 17th June 2000.
ABSTRACT
Secondary-ion mass spectrometry (SIMS) is an attractive method for elemental depth profiling for nitrided stainless steel. However, if taken at face value, the results suggest migration of Mo and Cr from the nitrogen-rich layer. More plausibly, the results indicate the presence of significant matrix effects, and this conclusion casts doubt on the interpretation of all the SIMS depth profiles, including that of nitrogen. We explored this question by examining standard samples prepared by nitrogen-ion implantation and comparing assays and depth profiles from SIMS, energy-dispersed X-ray microanalysis (EDX), heavy-ion elastic-recoil detection analysis (HI-ERDA) and X-ray photoelectron spectroscopy (XPS). We conclude that there are negligible matrix effects in the SIMS sputter yields of nitrogen and carbon, but that the yields of MoCs+ and CrCs+ ions are significantly affected by the concentration of nitrogen. Thus, the shape of the nitrogen and carbon depth profiles from SIMS can be taken at face value. HI-ERDA gives depth profiles of the same quality as SIMS, but is limited to a relatively thin nitrogen-containing layer. Results from EDX, HI-ERDA and XPS show that the relative concentrations averaged over the treated layer of the main metals in the alloy are the same as in the bulk material. Detailed examination of the peak positions and widths in XPS shows a clear chemical association between the nitrogen in the treated layer and Cr and Mo, and probably also an N–Fe association, but none between nitrogen and Ni. These results support a model of the kinetics of nitriding in austenitic stainless steel.
1. INTRODUCTION
Stainless steel hardened by nitriding is potentially such a useful material, and plasma nitriding gives such promise of a commercially practicable method of producing it, that much effort world wide is now being devoted to realising this potential.1, 2, 3, 4, 5 As in many other fields, a significant issue for this research is the characterisation of treated samples, for the purpose of comparing the efficacy of different treatment processes. Many diagnostic methods are used; among them are techniques for determining the composition of the treated layer. These range from methods familiar in metallurgy, such as glow-discharge optical spectroscopy, to the most sophisticated techniques developed in modern surface science. A feature of all methods is the need for calibration: whether one is measuring the yield of photons, electrons or ions, there is always the question of relating the observed yield to the concentration of the various species in the material under study. The work reported in this paper was prompted by just such a question of calibration, in this case in the results of secondary-ion mass spectrometry (SIMS) on samples of nitrided AISI 316 stainless steel.
Figure 1 shows a typical SIMS elemental depth profile from a nitrided sample. (Experimental details are given in §§ 2.1 and 2.2.) There are many interesting features in these data, not least the shape of the profiles for carbon and nitrogen. However, the profiles for the four main alloy elements indicate that the interpretation may not be straightforward. All four metals show a lower ion-current ratio ℐMCs+ in the nitrogen-containing layer compared with the bulk. This is to be expected from sputtering theory, which indicates that the ion-current ratio of a species M should be proportional to its atomic concentration cM (atom %), and cM values for the metal elements are reduced by the presence of the nitrogen. But closer inspection shows that the details do not match this explanation. Table 1 gives the ratio of ion-current ratios in the treated layer to the bulk for the four main alloy elements. A straightforward interpretation would explain the value for iron as reflecting a ~25 at. % concentration of nitrogen in the treated layer. However, one would then expect the values to be the same for all the metals, and clearly they are not. Either there has been migration of Cr and Mo from the treated layer, or the ion-current ratios of these elements are influenced by the presence of nitrogen differently from those of Fe and Ni. Given that Fe is the main constituent of the alloy (~65 at. %), there may even be evidence that ℐNiCs+ is behaving in an opposite manner from ℐCrCs+ and ℐMoCs+.

Influences of this sort are referred to as ‘matrix effects’; their presence clearly complicates the interpretation of depth profiles. One can no longer assume that, for example, a halving of ℐMCs+ implies a halving of cM; rather there may be a change in the calibration factor relating these two. Of the elements profiled in Fig. 1, most interest perhaps lies in nitrogen and carbon, but there is no reason why the profiles of these should be less affected by matrix effects than the profiles of the meta...
Table of contents
- Cover
- Half Title
- Title Page
- Copyright Page
- Table of Contents
- Preface
- Conference Overview
- Section One: Selected Background Literature to Expanded Austenite
- Section Two: General Thermochemical Treatments of Stainless Steel
- Section Three: Theoretical and Experimental Nature of S Phase
- Section Four: Industrial Processing Using S Phase Technology
- Index