Central Venous Pressure
eBook - ePub

Central Venous Pressure

Its Clinical Use and Role in Cardiovascular Dynamics

W. J. Russell

Share book
  1. 84 pages
  2. English
  3. ePUB (mobile friendly)
  4. Available on iOS & Android
eBook - ePub

Central Venous Pressure

Its Clinical Use and Role in Cardiovascular Dynamics

W. J. Russell

Book details
Book preview
Table of contents
Citations

About This Book

Central Venous Pressure: Its Clinical Use and Role in Cardiovascular Dynamics focuses on the clinical applications of central venous pressure and the role it plays in cardiovascular dynamics. This book discusses the clinical need to measure central venous pressure, describes the apparatus and its use, and considers the interpretation of the measurements. This text is comprised of five chapters divided into two sections and begins by introducing the reader to the cardiovascular system and its function; the significance of the central venous pressure in cardiovascular dynamics; and the interaction between venous return and cardiac function. The discussion then turns to the principles and techniques of measuring cardiac output and evaluation of central venous pressure. Two factors that affect the normal range, the intrathoracic pressure and the reference level, are highlighted. The final chapter explains the use of the central venous or right atrial pressure in clinical practice to detect changes in blood volume and testing of the equivocal level of central venous pressure using a fluid load or isoprenaline. This book is intended for physiologists and clinicians, including surgeons and anesthesiologists.

Frequently asked questions

How do I cancel my subscription?
Simply head over to the account section in settings and click on ā€œCancel Subscriptionā€ - itā€™s as simple as that. After you cancel, your membership will stay active for the remainder of the time youā€™ve paid for. Learn more here.
Can/how do I download books?
At the moment all of our mobile-responsive ePub books are available to download via the app. Most of our PDFs are also available to download and we're working on making the final remaining ones downloadable now. Learn more here.
What is the difference between the pricing plans?
Both plans give you full access to the library and all of Perlegoā€™s features. The only differences are the price and subscription period: With the annual plan youā€™ll save around 30% compared to 12 months on the monthly plan.
What is Perlego?
We are an online textbook subscription service, where you can get access to an entire online library for less than the price of a single book per month. With over 1 million books across 1000+ topics, weā€™ve got you covered! Learn more here.
Do you support text-to-speech?
Look out for the read-aloud symbol on your next book to see if you can listen to it. The read-aloud tool reads text aloud for you, highlighting the text as it is being read. You can pause it, speed it up and slow it down. Learn more here.
Is Central Venous Pressure an online PDF/ePUB?
Yes, you can access Central Venous Pressure by W. J. Russell in PDF and/or ePUB format, as well as other popular books in Biological Sciences & Human Anatomy & Physiology. We have over one million books available in our catalogue for you to explore.
II
CENTRAL VENOUS PRESSURE IN CLINICAL USE

Assessment of Cardiac Output

Publisher Summary

This chapter discusses the assessment of the cardiac output. The most critical transport requirement in the body is that for oxygen. For many tissues, an adequate oxygenation is important. It is the oxygen supply that is limited by a flow in hypotension, and the consequent enforced reduction in oxidative metabolism may damage some tissues. Many factors affect the need of the tissues for oxygen. The important indicators for assessing the adequacy of the cardiac output are found at the capillary level. A good capillary filling with a warm pink skin indicates an adequate cardiac output; a pale or blue cold skin suggests poor perfusion and implies that the output is inadequate. The function of tissues can also be used in the assessment. If brain perfusion is impaired and poor kidney perfusion is revealed by a low urinary output, it is probable that the cardiac output is inadequate for the patientā€™s requirements. When the cardiac output is low, the blood pressure is usually low and the pulse rate is high.
Even when the physiology and dynamic pathology of the cardiovascular system are understood the practical details of central venous pressure measurement remain to be mastered.
The measurement is not appropriate in every patient but it should be made whenever the cardiovascular dynamics are abnormal. Clinically this may be obvious as pulmonary oedema or, more commonly, as an inadequate cardiac output. Thus an assessment of the adequacy of the cardiac output will often be the first consideration.
If it is decided that the central venous pressure should be measured, then the practical matters of technique and evaluation of the measurements follow.
The most critical transport requirement in the body is that for oxygen. For many tissues an adequate oxygenation is supremely important. It is the oxygen supply that is limited by flow in hypotension (Crowell, 1970) and the consequent enforced reduction in oxidative metabolism may damage some tissues. Many factors affect the need of the tissues for oxygen. Even at rest the individual requirement may be greatly different; from, for example, an abnormal low in myxoedema, to a very high level in fever or during shivering.
Important indicators for assessing the adequacy of cardiac output are found at capillary level. Good capillary filling with a warm pink skin indicates an adequate cardiac output; a pale or blue cold skin suggests poor perfusion and implies that output is inadequate. The function of tissues can also be used in the assessment. If brain perfusion is impaired as shown by a clouded consciousness and poor kidney perfusion is revealed by a low urinary output, it is probable that the cardiac output is inadequate for the patientā€™s requirements (Motsay et al., 1970). When the cardiac output is low, the blood pressure is usually low (below 90/40 mmHg) and the pulse rate high (an indication of increased sympathetic activity in a heart with normal conduction).
A central venous catheter should be introduced if the patient has an inadequate cardiac output. If the catheter is placed in the right atrium, measurement of central venous oxygen contentā€”an index of tissue oxygenationā€”can provide a further guide to assessment of the general level of perfusion. Even the less sophisticated measurement of oxygen saturation has a good correlation with the cardiac output (Figure 19) in shock (Lee, et al., 1972). It has also been found suitable as a guide in patients with myocardial infarction (Goldman et al., 1968) and in severely ill cardiac patients (Scheinman, Brown and Rapaport, 1969).
image
Figure 19 The relationship between oxygen saturation and cardiac output in 36 patients, 13 of whom were considered to be in shock. The output has been standardized as the cardiac index. The correlation coefficient is +0.84 with a regression equation of cardiac index (y) against saturation (x) of y = 0.0974x āˆ’ 3.76 (Drawn from the data of Lee et al., 1972)
In normal subjects the relationship between the oxygen saturation of blood from the superior vena cava, right atrium, right ventricle and pulmonary artery is very close (Barrat-Boyes and Wood, 1957). This relationship is less close in low cardiac output states; in particular, a blood sample from the superior vena cava tends to have a higher oxygen saturation than do samples from the other sites (Lee et al., 1972; Scheinman, Brown and Rapaport, 1969). However, from any of these sites changes in saturation have the same implicationā€”that a change in perfusion has occurred.

The Technique of Measurement

Publisher Summary

This chapter discusses the techniques to measure central venous pressure (CVP). A catheter or cannula may be inserted into an external jugular vein to give an approximate value for the CVP. The procedure is simple and convenient. When the central venous catheter is positioned correctly, the pressure reading shows a small fluctuation in time with the patientā€™s respiration. This fluctuation is because of a slight change in the intrathoracic pressure that occurs with respiratory movements. However, if the catheter is misplaced into the internal jugular vein, respiratory fluctuation may still occur but the reading will be 2ā€“6 cm H2O too high. The reference level is extremely important when measuring central venous or atrial pressures because these differ only slightly from the atmospheric pressureā€”generally by less than the equivalent of 10 cm of water or saline. The common methods of measurement depend on the presence of a column of liquid between the reference point in the right atrium or central vein and the actual pressure-measuring device.

Insertion of a central venous catheter

Today most clinicians prefer to avoid the inferior vena cava because of the risk of sepsis in the groin (Bansmer et al., 1958) and because any increase in abdominal pressure makes the readings unreliable (Guyton and Adkins, 1954; Figure 20). The increase in abdominal pressure may be caused by diseaseā€”for example, a large amount of ascites; or by a normal situationā€”such as the enlarged uterus of late pregnancy which may elevate the pressure in the inferior vena cava by as much as 20 cm H2O (Kerr, Scott and Samuel, 1964; Colditz, 1970). Often a catheter is passed from the cubital fossa to the superior vena cava or one of its central tributaries, either by a cut-down, Seldinger technique (Seldinger, 1953; Doty, 1969) or a percutaneous stab (Webre and Arens, 1973). Sometimes more direct approaches to a central vein are made (Figure 21) either by Aubaniacā€™s (1952) infraclavicular approach to the subclavian vein (Davidson et al., 1963), a supraclavicular subclavian technique (Yoffa, 1965) or a direct approach into the internal jugular vein (English et al., 1969). With any of these techniques the catheter should be radio-opaque or have a radio-opaque line so that the position of the end in the chest may be determined by radiography (Woods et al., 1974).