A general overview of the use of utility distribution poles, including for electric supply and communications applications
Overhead Distribution Lines: Design and Applications provides information on the design and use of power and communication distribution lines. An excellent resource for those in the power and communication utilities industry, this book presents information on the physical characteristics of utility poles, overhead supply and communication cables, installation practices, joint-usage issues, and safety rules, including the National Electrical Safety Code (NESC), California-specific rules, and others. It describes how to select the proper poles for specific applications. The especially valuable final chapter provides examples showing how it all works in practice, providing a background allowing more effective use of related industry software.
Rather than delving into detailed design and installation techniques, this book serves as an overview for engineers and non-technical audiences alike. At the same time, it serves as a compendium of technical information not readily available elsewhere. This unique book:
Offers an overview of pole structures, pole installation and maintenance, wires and cables, and cable installation and maintenance—with examples
Provides information on national standards documents such as the National Electrical Safety Code (NESC), ANSI O5.1, California General Order 95, and more
Explores the "sag–tension" relationship between wires and poles
Includes appendices that cover properties of messenger strands, wireless attachments, solution of equations to determine sag, under uniform and point loads
Overhead Distribution Lines: Design and Applications offers readers an understanding of the basic principles and various issues related to electric supply and communications distribution lines. It is a valuable resource for utility engineers, as well as those without a technical background.
Frequently asked questions
Yes, you can cancel anytime from the Subscription tab in your account settings on the Perlego website. Your subscription will stay active until the end of your current billing period. Learn how to cancel your subscription.
At the moment all of our mobile-responsive ePub books are available to download via the app. Most of our PDFs are also available to download and we're working on making the final remaining ones downloadable now. Learn more here.
Perlego offers two plans: Essential and Complete
Essential is ideal for learners and professionals who enjoy exploring a wide range of subjects. Access the Essential Library with 800,000+ trusted titles and best-sellers across business, personal growth, and the humanities. Includes unlimited reading time and Standard Read Aloud voice.
Complete: Perfect for advanced learners and researchers needing full, unrestricted access. Unlock 1.4M+ books across hundreds of subjects, including academic and specialized titles. The Complete Plan also includes advanced features like Premium Read Aloud and Research Assistant.
Both plans are available with monthly, semester, or annual billing cycles.
We are an online textbook subscription service, where you can get access to an entire online library for less than the price of a single book per month. With over 1 million books across 1000+ topics, we’ve got you covered! Learn more here.
Look out for the read-aloud symbol on your next book to see if you can listen to it. The read-aloud tool reads text aloud for you, highlighting the text as it is being read. You can pause it, speed it up and slow it down. Learn more here.
Yes! You can use the Perlego app on both iOS or Android devices to read anytime, anywhere — even offline. Perfect for commutes or when you’re on the go. Please note we cannot support devices running on iOS 13 and Android 7 or earlier. Learn more about using the app.
Yes, you can access Overhead Distribution Lines by Lawrence M. Slavin in PDF and/or ePUB format, as well as other popular books in Physical Sciences & Energy. We have over one million books available in our catalogue for you to explore.
This manual presents a brief description of typical practices for the design, installation, and usage of overhead utility distribution lines, providing an understanding of the basic principles, and facilitating the subsequent pursuit of the technology and issues in greater detail, as desired or appropriate. It is not, however, the intention of this document to provide or duplicate existing detailed design, construction, or installation specifications and information as presently employed by the various electric supply and communications utilities for their overhead facilities. Such information is available within the individual utilities or their representative organizations.
Although some of the information in this manual is applicable to a variety of overhead applications, including high-voltage transmission lines, the focus of the information is on the local distribution systems, closer to the customer or subscriber end of the grid. This portion of the network is typically characterized by efficient joint-use applications in which electric supply and communications facilities are in reasonably close proximity, supported on the same physical structures, but with strict rules and guidelines to help ensure reliable operation and the safety of both the public and the utility workers. These systems are characterized by significant variability between the facilities supported on each pole, and frequent changes based on customer need, and are generally not subject to the same level of physical design detail as the electrical transmission lines. Indeed, it would be neither practical nor cost-effective to perform a detailed, sophisticated structural analysis on every pole in a distribution line. In contrast, long-distance high-voltage power transmission facilities, along the same transmission line, are relative invariable and unchanging, with relatively uniform spans, and require the efforts of experienced structural engineers, often supported by the use of sophisticated software tools, to cost-effectively design reliable, safe overhead facilities.
This manual is divided into 10 sections or chapters. The background, including a description of the two general categories of construction methods relevant to outdoor utility lines, is provided in Chapter 1, including the overall characteristics and relative advantages and disadvantages represented by each category. Chapter 2 contains a description of pole structures and their physical characteristics, while Chapter 3 provides an overview of their installation, operation, and maintenance procedures. A description of the various types of suspended wires, conductors, and cables is contained in Chapter 4, and Chapter 5 discusses the methods of their installation. Chapters 6 (Strength and Loading) and 7 (Clearances) are primarily based on the rules of the National Electrical Safety Code (NESC®), which govern the physical design and construction of the overhead lines, to help ensure safe facilities for the public and utility workers. Chapter 8 explains the principles regarding wire sags (and related tensions) and provides methods for determining these values under various weather and operating conditions. Chapter 9 contains a brief description of General Order 95, which governs overhead utility lines in California, and how it compares to the NESC. Example calculations are included in Chapter 10 for estimating the physical status of pole systems subject to storm loads. Additional details and explanatory information supporting the various chapters is contained in Appendices A–E. A glossary of terms and a list of references are also provided.
1.2 Background
There are two basic modes of construction for outdoor utility lines for electric power supply and communication systems:
Belowground (or underground) plant consisting of an array of parallel conduit paths, spanning the distance between manholes, typically located parallel to a main thoroughfare or highway; or, for more local distribution applications, direct burial of the cables within the soil, possibly placed along a road or street, with buried service drops to the residences. Routine access to such distribution facilities is typically provided by flush-mounted handholes or above ground terminals and pedestals.
Aerial/overhead plant in which the cables are individually suspended between utility structures, including tall structures or towers for high-voltage transmission lines, spaced hundreds, or possibly thousands, of feet apart; or relatively short structures for distribution applications, typically individual poles, spaced up to a few hundred feet apart.
For both these modes of construction, the requirements and guidelines for the installation and operation of power supply and communications lines, including the shared usage of facilities (poles, underground conduit systems, trenches), are provided in utility industry standards and documents, the most significant of which is the NESC. Both construction methods are commonly used in the industry, with an increasing amount of belowground distribution facilities being placed relative to aerial plant in more recent decades, primarily driven by regulations. For example, the large majority of new construction in local (residential) subdivisions deploys belowground facilities, in response to the demands of communities and various levels of government for a greater portion of belowground construction along roads and thoroughfares, primarily due to esthetic considerations and safety concerns. Utility pole collisions account for a significant fraction of automotive fatalities along the nation's roads and highways, for which the U.S. Federal Highway Administration, as well as the individual states, therefore provide appropriate guidelines for their usage (FHA 1993; AASHTO 2011).
A description of belowground cable applications, including conduit and duct applications, is provided in ASCE Manual of Practice No. 118 (ASCE 2009). Figure 1.1 illustrates typical belowground (underground conduit and direct-buried) construction alternatives.
The extensive conduit facilities of underground plant are generally appropriate for limited applications, such as associated with the trunk or feeder portions of the traditional telecommunications network, owing to the high cost of this method of construction. However, the availability of several vacant conduits does provide flexibility, including the capability to postpone installation of expensive trunk or feeder facilities (fiber-optic, etc.) until the need arises. Such expensive underground conduit systems are also the only viable alternative in metropolitan or large urban areas where overhead lines and/or future digging are not practical options. In comparison, direct-buried plant is a lower cost method for placing individual cables belowground between any desired termination points, but lacks any flexibility with respect to future additions or replacements. While the placement of utility lines belowground, using either method of construction, avoids much of the potential damage resulting from extreme weather events, there is nonetheless greater vulnerability during incidents of flooding and accidental damage during excavation work in the area.
Figure 1.1 Typical belowground construction.
Although not esthetically pleasing, the ubiquitous overhead lines throughout the United States – supported by possibly as many as 200 million utility poles – provide many important benefits, and is the reason these structures and suspended lines continue to be widely used. Individual distribution poles, or even lattice transmission towers, require minimum real estate at the ground level, and allow new lines to be readily deployed in available overhead space. This includes otherwise difficult crossing applications, or where expensive belowground construction methods (e.g. directional drilling) would be required, such as at highways, railroads, and waterways. Overhead installations avoid the many possible issues encountered when attempting to perform construction beneath the surface in various or unknown belowground conditions, often in the presence of existing belowground facilities. The latter situation can be particularly hazardous, especially when power or gas lines are in the vicinity. The use of mandatory “call-before-dig” rules, and related utility locating practices, are not infallible, and unfortunate accidents may occur in spite of such precautions.
Apart from natural or man-made disasters, overhead lines are exposed to environmental stresses that are generally less severe than the persistent wet and corrosive surroundings that can be found belowground. As a result, it is often more of a challenge to design the belowground cables and/or the associated conduit/manhole facilities with sufficient resistance to those degradation forces than where the cables are placed overhead. In addition, if degradation occurs, or water penetrates the belowground plant, their repair and replacement is more difficult, expensive, and time-consuming. In general, overhead lines are inherently significantly less expensive to install and maintain than belowground facilities, as well as being characterized by greater flexibility for the addition, rearrangement, and/or replacement of the supported lines and equipment.
Figure 1.2 illustrates a typical distribution utility pole application including sharing, or joint-use, of the pole for supporting electric power supply and communications (telephone, Cable/CATV) lines.
Figure 1.2 Typical joint-use utility pole application.
Source: Lawrence M. Slavin.
It is recognized that the increasing deployment of wireless technologies (cellular phones, satellite TV, etc.) has greatly impacted the communications industry, resulting in lost revenue for some of the ...