Seismic Design and Practice into the Next Century
eBook - ePub

Seismic Design and Practice into the Next Century

Proceedings of the 6th SECED conference, Oxford, 26-27 March 1998

  1. 550 pages
  2. English
  3. ePUB (mobile friendly)
  4. Available on iOS & Android
eBook - ePub

Seismic Design and Practice into the Next Century

Proceedings of the 6th SECED conference, Oxford, 26-27 March 1998

About this book

The papers, from 18 countries in Europe and elsewhere, contain discussions of quite radical innovations in material technology, design philosophy, experimental techniques and analytical approaches that will affect seismic design practice into the next century. Papers are organised into 9 sections: Ground motion and seismic hazard studies; Seismic design of foundations; Seismic design of steel, concrete and masonry buildings; Seismic design of offshore, nuclear and petrochemical installations; Seismic design of bridges, dock and power station structures; Repair and strengthening of bridges and buildings; Active and passive methods of seismic control; Dynamic testing methods; Seismic codes of practice. The proceedings will provide essential material for all those from both industrial and research organisations needing to keep in touch with the state-of-the-art in earthquake engineering and related earch sciences.

Frequently asked questions

Yes, you can cancel anytime from the Subscription tab in your account settings on the Perlego website. Your subscription will stay active until the end of your current billing period. Learn how to cancel your subscription.
No, books cannot be downloaded as external files, such as PDFs, for use outside of Perlego. However, you can download books within the Perlego app for offline reading on mobile or tablet. Learn more here.
Perlego offers two plans: Essential and Complete
  • Essential is ideal for learners and professionals who enjoy exploring a wide range of subjects. Access the Essential Library with 800,000+ trusted titles and best-sellers across business, personal growth, and the humanities. Includes unlimited reading time and Standard Read Aloud voice.
  • Complete: Perfect for advanced learners and researchers needing full, unrestricted access. Unlock 1.4M+ books across hundreds of subjects, including academic and specialized titles. The Complete Plan also includes advanced features like Premium Read Aloud and Research Assistant.
Both plans are available with monthly, semester, or annual billing cycles.
We are an online textbook subscription service, where you can get access to an entire online library for less than the price of a single book per month. With over 1 million books across 1000+ topics, we’ve got you covered! Learn more here.
Look out for the read-aloud symbol on your next book to see if you can listen to it. The read-aloud tool reads text aloud for you, highlighting the text as it is being read. You can pause it, speed it up and slow it down. Learn more here.
Yes! You can use the Perlego app on both iOS or Android devices to read anytime, anywhere — even offline. Perfect for commutes or when you’re on the go.
Please note we cannot support devices running on iOS 13 and Android 7 or earlier. Learn more about using the app.
Yes, you can access Seismic Design and Practice into the Next Century by Edmund Booth in PDF and/or ePUB format, as well as other popular books in Technologie et ingénierie & Ingénierie civile. We have over one million books available in our catalogue for you to explore.

Information

Seismic design of steel, concrete and masonry buildings

Seismic performance of semi-rigid steel frames

F. Danesh
Faculty of Civil Engineering, K.N.Toosi University, Tehran, Iran
ABSTRACT: Experimental results indicate that many connections in steel frames show semi-rigid behaviour. There is a great deal of data on the performance of different types of connections in the literature, but the dynamic response of these frames has not received much attention. The objective of this study is to investigate the seismic behaviour of two-storey semi-rigid frames through the pseudo-dynamic testing. Analytical models for analyzing these frames are discussed. In order to investigate the influence of the dynamic characteristics of the frames and time history records, a number of frames with different configurations are subjected to five earthquake records. In this study, the behaviour factors of partial strength semi-rigid steel frames are evaluated and the dynamic response of these frames are compared with both rigid and full strength semi-rigid frames. It is shown from experimental and analytical investigations that the semi-rigid steel frames represented good performance for ground motions and attracted less storey shear forces than rigid one. By virtue of the elongated period of vibration and energy dissipation in connections, the response of the partial strength semi-rigid frame as a whole is well below its rigid counterpart.

1 Introduction

The results obtained from previous investigations clearly indicated that the semi-rigid-connection is feasible and indeed more economical than the rigidly-connected frame, and also show that the optimum seismic design solution is not necessarily a rigidly connected frame.
Experimental work done by Elnashai and Elghazouli (1992) indicated that semi-rigid frames do exhibit a ductile and stable hysteretic behaviour. Although the stiffness and capacity of semi-rigid frames are both lower than similar rigid frames under monotonic and cyclic loading, the response under earthquake loading largely depends on the dynamic characteristics of both the frames and the input motion. In many cases, the response of semi-rigidly connected frames may be superior to rigid frames, provided that stable hysteretic behaviour is ensured.
Kuwamura and Suzuki (1992) indicated that any welded joints, whatever excellent workmanship is employed, eventually suffer fatigue fracture. Many modern steel buildings that suffered from local failures during the 1994 Northridge earthquake, illustrated that the dominant local failure occurs in welded beam-to-column connections (Bertero et al., 1994).
Today, the seismic behaviour of semi-rigid steel frames is a new field in research and represent that this type of connection has some benefits against rigid connection. But there is not enough information to predict the real behaviour of semi-rigid connections and few tests have been done in this area.
The main objective of this experimental and analytical work is to study the performance of semi-rigid steel frames under cyclic and dynamic loads. For this purpose, five two-storey steel frames, one rigid and four semi-rigid steel frames were tested. To compare experimental results with analysis and to investigate the dynamic characteristics of the frames and ground motions, many frames with different configuration are subjected to different records. The results of experimental and analytical investigation are presented and discussed in the following sections.

2 EXPERIMENTAL INVESTIGATIONS

2.1 Testing procedure

Five two-storey steel frames have been tested under cyclic and dynamic loads. These comprise one rigid and four semi-rigid structures, the later with different connection strengths. The pseudo-dynamic testing method was used for the dynamic test.
To facilitate testing, the frame was placed horizontally. The different parts of the assembly were adequately prestressed to form a self-reacting frame. An actuator which imposes displacements was connected to the end of the beam at the second floor level whilst another actuator operated in force control was fixed to the end of the beam at the first floor level. A third actuator with two hinges to allow for in-plane movement was installed at the top of the column to apply an axial load. In the rigid steel frame, the flanges and the web of the beam were fully welded to the flange of the column. Top and seat angles with double web angles were used for the connections in the semi-rigid frames.
To reduce the risk of shear failure of the panel zone, two stiffeners were welded to the flange and the web of the column. In all the models a constant axial load was applied at the top of the column by means of hydraulic jack
The details of the connections for each semi-rigid model are given in Table 1. The connections in these models were designed as partial strength semi-rigid connection with a moment capacity which varied between 30% and 70% of the plastic moment of the connected beams.
Table 1
C...

Table of contents

  1. Cover
  2. Half Title
  3. Title Page
  4. Copyright Page
  5. Table of Contents
  6. Foreword
  7. Keynote papers
  8. Seismic design of steel, concrete and masonry buildings
  9. Seismic design of foundations
  10. Ground motion and seismic hazard studies
  11. Seismic design of offshore, nuclear and petrochemical installations
  12. Seismic design of bridges, dock and power station structures
  13. Dynamic testing methods
  14. Active and passive methods of seismic control
  15. Seismic codes of practice
  16. Repair and strengthening of bridges and buildings
  17. Author index