
Brachytherapy Physics, 2nd Edition
Monograph No. 31
- English
- PDF
- Available on iOS & Android
About this book
During the years since the first edition of the AAPM Brachytherapy Physics book was published, both high dose rate and low dose rate brachytherapy has flourished. This modality - which at that time was used in limited forms for a few disease sites and rarely offered outside academic institutions - is now applied at most radiation oncology centers to a substantial number of patients for a multitude of disease sites and with a broad spectrum of approaches. Major changes include improved imaging and targeting accuracy and the revision of the dosimetric formalism of AAPM Task Group 43.This book is organized into the following sections: Fundamentals of sources and delivery systems, and the radiobiological rationale for brachytherapy. Source specification parameters, calculation formalisms, target localization techniques, and computer algorithms used in modern brachytherapy treatment planning. Interstitial implant methods: classical system: checking dosimetry of, and communicating about, implants: implant design, optimization, and quality evaluation and reporting. In-depth reviews of clinical applications of interstitial implants of the prostate, the head and neck and the breast.Gynecological brachytherapy. Less conventional forms of brachytherapy, e.g., using miniature x-ray tubes, hyperthermia and radioactive microspheres.
Frequently asked questions
- Essential is ideal for learners and professionals who enjoy exploring a wide range of subjects. Access the Essential Library with 800,000+ trusted titles and best-sellers across business, personal growth, and the humanities. Includes unlimited reading time and Standard Read Aloud voice.
- Complete: Perfect for advanced learners and researchers needing full, unrestricted access. Unlock 1.4M+ books across hundreds of subjects, including academic and specialized titles. The Complete Plan also includes advanced features like Premium Read Aloud and Research Assistant.
Please note we cannot support devices running on iOS 13 and Android 7 or earlier. Learn more about using the app.
Information
Table of contents
- CHAPTER 1: Overview of Brachytherapy Physics
- CHAPTER 2: Radiobiology: A Briefing for the Brachytherapist
- CHAPTER 3: Sources and Delivery Systems I: Radionuclides
- CHAPTER 4: LDR Sources: Design and Delivery Systems
- CHAPTER 5: Quality Management of Low Dose Rate Brachytherapy Sources
- CHAPTER 6: High Dose Rate Sources and Delivery Systems
- CHAPTER 7: Quality Assurance for High Dose Rate Remote Afterloaders: Safety Standards for Clinical Implementation of High-Activity Brachytherapy Sources
- CHAPTER 8: Continuous Low Dose Rate and Pulsed Dose Rate Remote Afterloader Units
- CHAPTER 9: An Aperçu of Codes, Directives, Guidances, Notices, and Regulations in Brachytherapy
- CHAPTER 10: Brachytherapy Facility Design
- CHAPTER 11: Calibration for Brachytherapy Sources
- CHAPTER 12: Localization, Part I: Radiographic Methods and Accuracy
- CHAPTER 13: Localization II: Volume Imaging Techniques and Accuracy for Brachytherapy Dosimetry
- CHAPTER 14: Semiempirical Dose-Calculation Models in Brachytherapy
- CHAPTER 15: Quantitative Dosimetry Methods for Brachytherapy
- CHAPTER 16: The TG-43 Brachytherapy Dose Calculation Formalism
- CHAPTER 17: Treatment Planning Considerations of Brachytherapy Procedures
- CHAPTER 18: Systems 1B Manchester Planar and Volume Implants and the Paris System
- CHAPTER 19: Quimby-Based Brachytherapy Systems
- CHAPTER 20: Implant Design and Execution
- CHAPTER 21: Advanced 3-D Planning
- CHAPTER 22: Optimization in Brachytherapy
- CHAPTER 23: QA Review of Brachytherapy Treatment Plans
- CHAPTER 24: Quality Management for Interstitial Implants
- CHAPTER 25: Post-Implant Evaluation
- CHAPTER 26: ICRU Recommended Dose and Volume Specifications for Reporting Interstitial Brachytherapy
- CHAPTER 27: Intraoperative Radiation Therapy (IORT)
- CHAPTER 28: Introduction to Prostate Brachytherapy
- CHAPTER 29: Permanent Prostate Brachytherapy Treatment Planning
- CHAPTER 30: Treatment Delivery in Prostate LDR Brachytherapy
- CHAPTER 31: Post Implant Evaluation
- CHAPTER 32: HDR Brachytherapy for Prostate
- CHAPTER 33: Modern Advances in Prostate Brachytherapy
- CHAPTER 34: Episcleral Eye Plaques for Treatment of Intraocular Malignancies and Benign Diseases
- CHAPTER 35: Pterygium Brachytherapy Physics
- CHAPTER 35: Brachytherapy for Brain Tumors
- CHAPTER 37: Review of Head and Neck Brachytherapy
- CHAPTER 38: History and Rationale for Accelerated Partial Breast Irradiation (APBI)
- CHAPTER 39: Breast Interstitial Implant and Treatment Planning
- CHAPTER 40: Partial Breast Irradiation Using the MammoSite® Radiation Therapy System
- CHAPTER 41: Brachytherapy for Gynecological Malignancies
- CHAPTER 42: Volume Imaging in Gynecological Brachytherapy
- CHAPTER 43: Applicator Design and Dose Distributions
- CHAPTER 44: Manchester System for Gynecological Applications
- CHAPTER 45: Intracavitary Brachytherapy Applicators and UT M. D. Anderson Cancer Center Intracavitary Brachytherapy Techniques
- CHAPTER 46: ICRU Reporting for Cervical Brachytherapy
- CHAPTER 47: Physics of Uterine Corpus Brachytherapy
- CHAPTER 48: Changing from Low Dose Rate to High Dose Rate Intracavitary Gynecological Brachytherapy
- CHAPTER 49: Gynecological Interstitial Implants
- CHAPTER 50: Intravascular Brachytherapy
- CHAPTER 51: Brachytherapy with Miniature Electronic X-ray Sources
- CHAPTER 52: Thermal Therapy for Cancer
- CHAPTER 53: Radiofrequency Ablation
- CHAPTER 54: Microspheres as Microbrachytherapy
- COMPILED REFERENCES