Applied Technologies in Pulmonary Medicine
eBook - ePub

Applied Technologies in Pulmonary Medicine

A. M. Esquinas

Share book
  1. 270 pages
  2. English
  3. ePUB (mobile friendly)
  4. Available on iOS & Android
eBook - ePub

Applied Technologies in Pulmonary Medicine

A. M. Esquinas

Book details
Book preview
Table of contents
Citations

About This Book

This book is based on a selection of the most original articles published in the past year on new technological advances in the diagnosis and treatment of respiratory diseases. The authors of these papers were invited to contribute to this volume with critical reviews of their recent results and a discussion of the clinical implications of these findings. Technical innovations in the treatment of respiratory diseases involve many aspects from basic physics to pathophysiology and clinical experience in pulmonary and critical care medicine. The book therefore covers a broad spectrum of topics including mechanical ventilation, ventilator modes, new pharmacological treatments during ventilation, prevention of ventilator-associated infections, technologies in anesthesiology, pulmonary rehabilitation, telemonitoring in pediatric and neonatal critical care and assistance in chronic respiratory failure. Diagnostic methods such as polysomnography and ultrasound are considered as well as cardiopulmonary resuscitation methods and new options in inhalation therapies. Furthermore, the role of the environment in respiratory health problems is analyzed, and organizational issues in disaster management and intensive care are highlighted. Intended to help clinicians understand the highly technological diagnostic and therapeutic methods available today, this book will be indispensable for anyone caring for children or adults with respiratory problems, both in the ICU and in daily practice.

Frequently asked questions

How do I cancel my subscription?
Simply head over to the account section in settings and click on “Cancel Subscription” - it’s as simple as that. After you cancel, your membership will stay active for the remainder of the time you’ve paid for. Learn more here.
Can/how do I download books?
At the moment all of our mobile-responsive ePub books are available to download via the app. Most of our PDFs are also available to download and we're working on making the final remaining ones downloadable now. Learn more here.
What is the difference between the pricing plans?
Both plans give you full access to the library and all of Perlego’s features. The only differences are the price and subscription period: With the annual plan you’ll save around 30% compared to 12 months on the monthly plan.
What is Perlego?
We are an online textbook subscription service, where you can get access to an entire online library for less than the price of a single book per month. With over 1 million books across 1000+ topics, we’ve got you covered! Learn more here.
Do you support text-to-speech?
Look out for the read-aloud symbol on your next book to see if you can listen to it. The read-aloud tool reads text aloud for you, highlighting the text as it is being read. You can pause it, speed it up and slow it down. Learn more here.
Is Applied Technologies in Pulmonary Medicine an online PDF/ePUB?
Yes, you can access Applied Technologies in Pulmonary Medicine by A. M. Esquinas in PDF and/or ePUB format, as well as other popular books in Medicine & Perinatology & Neonatology. We have over one million books available in our catalogue for you to explore.

Information

Publisher
S. Karger
Year
2010
ISBN
9783805595858
Applied Technologies in Specific Clinical Situations
Technology in Sleep Pulmonary Disorders
Esquinas AM (ed): Applied Technologies in Pulmonary Medicine. Basel, Karger, 2011, pp 46–50
______________________

Thermal Infrared Imaging during Polysomnography: Has the Time Come to Unwire the ‘Wired’ Subjects?

Jayasimha N. Murthya · Ioannis Pavlidisb
aDivisions of Pulmonary, Critical Care and Sleep Medicine, University of Texas Health Science Center, and bDepartment of Computer Science, University of Houston, Houston, Tex., USA
______________________
Abbreviations
ATHEMOS
Automated thermal monitoring system
BCI
Bayesian credible interval
Îș (kappa)
Chance-corrected agreement
Pn
Nasal pressure – airflow monitoring device routinely used in polysomnography
REM
Rapid eye movement
RERA
Respiratory effort-related arousals
SDB
Sleep disordered breathing – encompasses a wide variety of disorders characterized by breathing abnormalities during sleep such as obstructive sleep apnea, central sleep apnea, etc.
TIRI
Thermal infrared imaging
Untreated SDB is a very prevalent problem and can cause daytime sleepiness as well as have far-reaching socioeconomic and health-related consequences. A summary of statistics from three pooled studies estimated that 20% of adults with a body mass index between 25 and 28 kg/m2 have SDB based on an apnea-hypopnea index of >5 per hour [1]. Sleepiness is believed to have played a major role in causing disasters such as the Chernobyl and the Three Mile Island tragedies [2] and has been reported to be the most common cause of fatalities associated with motor vehicle accidents [3]. Untreated SDB is also associated with cardiovascular diseases [4].
Diagnosis of sleep apnea typically involves an overnight sleep study with simultaneous monitoring of airflow channels (Pn, oro-nasal thermistor), electrocardiogram, sleep staging by electroencephalography, electro oculography, and chin and leg electromyography in accordance with the Level 1 recommendations of the American Academy of Sleep Medicine [5]. However, conventional polysomnography has the potential to interfere with the ‘usual’ sleep pattern. A sizeable proportion of patients and normal volunteers who have never had a prior sleep study, experience the ‘first night effect’ characterized mainly by a decrease in sleep efficiency, prolongation of sleep-onset time, increase in REM sleep latency and a reduction in the total amount of REM sleep [6]. Additionally, it has been demonstrated that instrumentation during polysomnography affects body position during sleep [7] and thus impacts the diagnosis of SDB, the severity of which can increase during supine sleep. Moreover, bedside manipulation of sensors, in an effort to obtain high-quality data, may further disturb sleep and hinder our ability to obtain a true representation of the patient's usual sleep pattern. Thus, decreasing subject contact with monitoring equipment and testing in the ‘usual’ sleep environment may help counteract polysomnography's interference with sleep and SDB.
American Academy of Sleep Medicine recommends the use of thermistor as the airflow sensor for the diagnosis of apnea and Pn for the diagnosis of hypopnea as well as RERA [5]. While Pn can overestimate pathological events, especially when subjects change from nasal to predominantly oral breathing, the thermistor on the other hand lacks the sensitivity as compared to Pn, to detect subtle flow abnormalities such as hypopnea and RERAs. Non-contact airflow monitoring technology such as TIRI has the capability to monitor airflow during sleep without subject contact. This concept can be extended to include both laboratory-based and home-based sleep studies.

Description of TIRI

The principle of operation of TIRI is close to that of the oro-nasal thermistor in that both these methods sense thermal radiation. However, it is important to note the following differences between the thermistor and TIRI:
(1) TIRI can sense thermal information at a distance (contact-free), while the thermistor needs to be physically placed and tethered to patient's oro-nasal area, in the proximity of the thermal signal.
(2) TIRI acquires thermal information through natural radiation from the source as opposed to the thermistor which acquires thermal information by conduction when placed in the path of airflow. Theoretically, conduction is bidirectional and has an associated measurement error based on where and when the measurements are made. The accuracy also depends on the intensity as well as the magnitude of change in the thermal signal that is being measured. This error can be detrimental to the detection of subtle airflow abnormalities. TIRI, on the other hand, is an array (imaging sensor) and not just a point sensor-like thermistor. Therefore, it can be used to obtain a thermistor-like signal across time by averaging the thermal signal from all the points in the cross-sectional area of the visible nares, as well as provide thermal information over an extended two-dimensional surface. Analysis of signal as an evolving two-dimensional surface across increases the sensitivity of TIRI and may increase its ability to detect subtle airflow-related phenomena.
Thus, on theoretical grounds alone, one would expect TIRI to be considered a ‘virtual thermistor’ to perform at least as good as the oro-nasal thermistor [8]. Despite these inherent advantages of TIRI as compared to the thermistor, the following significant challenges had to be overcome to realize the translation of this technology for airflow monitoring:
(1) Virtual probing: Since there is no physical probe involved in TIRI, a computational method is needed to segment the nostrils in the image, thus creating a ‘virtual’ probe, where the measurement can be performed. The difference in the temperature of inspired and expired air brings about a temporal variation in the thermal signature of the nostrils. This fluctuating thermal signal helps in the differentiation of the nostrils (or mouth, if the subject is mouth-breathing) from the rest of the facial tissue. The nostrils can thus be segmented from the face with the nasal cartilages forming ‘colder’ boundaries around the thermal signal (fig. 1).
(2) Tracking: Because there is no tethering and the subject is free to move, a computational method is needed to track changes in position, so that the virtual probe stays always in place and the accuracy of measurement is preserved. Functional imaging such as TIRI that maps randomly changing thermophysiological function in a non-restrained subject requires a collaborative network of particle filter trackers based on advanced statistics (coalitional tracking [9]) to compensate for subject movement.
Img
Fig. 1. Temporal variance of nostril region in thermal imagery during breathing: (a) inspiration phase, (b) transition phase, (c) expiration phase, and (d) thermal color map. Note the cold boundaries (labeled ‘Boundaries’) of the nasal cartilages that allow the segmentation of nostrils from the rest of the facial tissue.
(3) Signal extraction: Assuming that virtual probing and tracking work well, they create the opportunity for a good measurement, but not the measurement in itself. Since there is no physical transducer that can produce an electronic signal in response to thermal signal, the signal has to be computationally generated. This has been achieved by continuous wavelet transformation on the normalized thermal signal under the assumption that the breathing component is the strongest part of the varying thermal signal.

Integration of TIRI with Polysomnography

The integrated hardware and software system we used in our preliminary study [10] is called ATHEMOS. The thermal signal acquired by the infrared camera and proce...