Safety Instrumented System Design: Techniques and Design Verification
eBook - ePub

Safety Instrumented System Design: Techniques and Design Verification

William Goble, Iwan Van Beurden

Buch teilen
  1. English
  2. ePUB (handyfreundlich)
  3. Über iOS und Android verfügbar
eBook - ePub

Safety Instrumented System Design: Techniques and Design Verification

William Goble, Iwan Van Beurden

Angaben zum Buch
Buchvorschau
Inhaltsverzeichnis
Quellenangaben

Über dieses Buch

This book provides an excellent description of the design phase of the SIS safety life cycle as defined in IEC 61511: 2016. It focuses on the fundamental concepts, starting with a description of the entire safety life cycle process and then explaining how the design steps—from conceptual design through design verification—fit into that process. The book: •Explains the advantages of the performance-based approach to design•Discusses minimum redundancy concepts•Addresses equipment qualification•Provides the theoretical background for the probabilistic calculations that are the foundation of performance verification•Covers recent advances in SIF verification modeling•Provides numerous examples to explain potentially confusing language from IEC 61511 and IEC 61508This is an excellent reference for professionals designing safety instrumented systems, as well as those who are seeking certification. Each chapter contains questions and answers similar to those found on professional certification exams for functional safety, and the appendices include statistics, probability, failure-rate data tables, and system architectures.

Häufig gestellte Fragen

Wie kann ich mein Abo kündigen?
Gehe einfach zum Kontobereich in den Einstellungen und klicke auf „Abo kündigen“ – ganz einfach. Nachdem du gekündigt hast, bleibt deine Mitgliedschaft für den verbleibenden Abozeitraum, den du bereits bezahlt hast, aktiv. Mehr Informationen hier.
(Wie) Kann ich Bücher herunterladen?
Derzeit stehen all unsere auf Mobilgeräte reagierenden ePub-Bücher zum Download über die App zur Verfügung. Die meisten unserer PDFs stehen ebenfalls zum Download bereit; wir arbeiten daran, auch die übrigen PDFs zum Download anzubieten, bei denen dies aktuell noch nicht möglich ist. Weitere Informationen hier.
Welcher Unterschied besteht bei den Preisen zwischen den Aboplänen?
Mit beiden Aboplänen erhältst du vollen Zugang zur Bibliothek und allen Funktionen von Perlego. Die einzigen Unterschiede bestehen im Preis und dem Abozeitraum: Mit dem Jahresabo sparst du auf 12 Monate gerechnet im Vergleich zum Monatsabo rund 30 %.
Was ist Perlego?
Wir sind ein Online-Abodienst für Lehrbücher, bei dem du für weniger als den Preis eines einzelnen Buches pro Monat Zugang zu einer ganzen Online-Bibliothek erhältst. Mit über 1 Million Büchern zu über 1.000 verschiedenen Themen haben wir bestimmt alles, was du brauchst! Weitere Informationen hier.
Unterstützt Perlego Text-zu-Sprache?
Achte auf das Symbol zum Vorlesen in deinem nächsten Buch, um zu sehen, ob du es dir auch anhören kannst. Bei diesem Tool wird dir Text laut vorgelesen, wobei der Text beim Vorlesen auch grafisch hervorgehoben wird. Du kannst das Vorlesen jederzeit anhalten, beschleunigen und verlangsamen. Weitere Informationen hier.
Ist Safety Instrumented System Design: Techniques and Design Verification als Online-PDF/ePub verfügbar?
Ja, du hast Zugang zu Safety Instrumented System Design: Techniques and Design Verification von William Goble, Iwan Van Beurden im PDF- und/oder ePub-Format sowie zu anderen beliebten Büchern aus Technology & Engineering & Mechanical Engineering. Aus unserem Katalog stehen dir über 1 Million Bücher zur Verfügung.
1
The SIS Safety Life Cycle
Introduction
The safety instrumented system (SIS) safety life cycle can be simply defined as an engineering process with design, analysis, and testing steps to ensure that SISs are effective in the key mission of:
Risk reduction
Optimal life-cycle cost of each system
The activities associated with the SIS safety life cycle start when the conceptual design of the facilities is complete, and stop when the facilities are completely decommissioned. The key activities associated with the SIS safety life cycle are analyzing risks and the need for risk reduction; establishing performance requirements for all safety functions in a system; implementing the system based on required performance criteria; and ensuring that the system is always operated and maintained correctly.
When the SIS safety life cycle is used with an existing system, the first step is to review and update the process hazard analysis and safety integrity level (SIL) selection. Given that information, the “as installed design” is documented and verified via analysis to determine if the design meets the verification requirements of current standards. Often it is discovered that the design is stronger than needed. In that case, there are opportunities to reduce ongosing maintenance costs by increasing the proof test interval. The same general design process is used with the objectives of:
Risk reduction
Ongoing optimal life-cycle cost going forward of each system
Functional Safety
The functional safety standard [1] published by the International Electrotechnical Commission (IEC), IEC 61508, defines safety as freedom from unacceptable risk. This is a good definition because it does not include “the elimination of risk.” Functional safety has been defined in IEC 61508 as “part of the overall safety relating to the equipment under control (EUC) and the EUC control system which depends on the correct functioning of the electrical/electronic/programmable electronic (E/E/PE) safety-related systems and other risk reduction measures.” Functional safety has a similar definition in IEC 61511 [2], which states “part of the overall safety relating to the process and the BPCS (basic process control system) which depends on the correct functioning of the SIS and other protection layers.” The phrase “correct functioning of the SIS” is key. A high level of functional safety means that an SIS will work correctly and with a high probability of successful operation. This success is achieved with the selection of high-quality equipment that is well suited for the intended purpose, and supported by a complete, high-quality operations and maintenance program.
Functional safety is therefore the key objective in SIS design. To achieve the right level of functional safety, several issues must be considered that may not be part of the normal design process for automation systems. These issues are provided as requirements in international standards.
Functional Safety Standards
For as long as automated systems have existed, engineers have designed automatic protection into them. Engineers often have specifically designed many of these automatic protection systems with pneumatic logic or electrical relays because these components tended to fail in a de-energized mode. Systems were designed to be safe when the automation de-energized. They were, in other words, designed to “fail safe.”
As the logic became more complicated, systems expanded to include large panels packed with relays and timers. It was, perhaps, natural for some engineers to convert this logic to a new “solid-state” design when these components became available in the late 1960s. Figure 1–1 illustrates an early solidstate module designed to implement “burner logic” using diode transistor logic (DTL), an early form of simple integrated circuit logic. Unfortunately, there was little consideration of the component failure modes of these designs. The simple DTL systems had a much higher probability of dangerous failure than conventional pneumatic and relay-based systems.
fig1-1.webp
Figure 1-1. Early Solid-State “Burner Logic” Design
When the first programmable electronic equipment, called programmable logic controllers (PLC), were created as an alternative to relay logic, many engineers immediately believed these new devices would be perfect for automatic protection applications. The functionality of these electronic devices, they felt, encompassed all that would be needed, and more. However, some engineers realized that the failure characteristics of solid-state/programmable electronic equipment might be quite different from traditional equipment. Other engineers were well aware of the “crash rate” and unpredictable failure modes of software systems at the time.
In fact, some government regulators banned the programmable electronic equipment for use in automatic protection functions. Others began working with industry experts to establish guidelines for using electronic equipment in “emergency shutdown” applications. Eventually, international standards committees were formed and standards covering the design and usage of equipment in SISs were published.
One of the more influential documents about SISs was titled “Programmable Electronic Systems in Safety Related Applications,” published by the Health and Safety Executive (HSE) in the United Kingdom [3, 4]. Early national standards for SISs include “Grundsätze für Rechner in Systemen mit Sicherheitsaufgaben,” first published in Germany [5, 6] in 1990, and ANSI/ISA-84.01-1996, “Application of Safety Instrumented Systems for the Process Industries,” [7] published in 1996 in the United States.
Many members of these national safety standards efforts became members of an international committee that eventually wrote IEC 61508. This standard began in the mid-1980s when the IEC Advisory Committee of Safety (...

Inhaltsverzeichnis