A one-stop guide to transformer ageing, presenting industrially relevant state-of-the-art diagnostic techniques backed by extensive research data

  • Offers a comprehensive coverage of transformer ageing topics including insulation materials, condition monitoring and diagnostic techniques
  • Features chapters on smart transformer monitoring frameworks, transformer life estimation and biodegradable oil
  • Highlights industrially relevant techniques adopted in electricity utilities, backed by extensive research

Häufig gestellte Fragen

Wie kann ich mein Abo kündigen?
Gehe einfach zum Kontobereich in den Einstellungen und klicke auf „Abo kündigen“ – ganz einfach. Nachdem du gekündigt hast, bleibt deine Mitgliedschaft für den verbleibenden Abozeitraum, den du bereits bezahlt hast, aktiv. Mehr Informationen hier.
(Wie) Kann ich Bücher herunterladen?
Derzeit stehen all unsere auf Mobilgeräte reagierenden ePub-Bücher zum Download über die App zur Verfügung. Die meisten unserer PDFs stehen ebenfalls zum Download bereit; wir arbeiten daran, auch die übrigen PDFs zum Download anzubieten, bei denen dies aktuell noch nicht möglich ist. Weitere Informationen hier.
Welcher Unterschied besteht bei den Preisen zwischen den Aboplänen?
Mit beiden Aboplänen erhältst du vollen Zugang zur Bibliothek und allen Funktionen von Perlego. Die einzigen Unterschiede bestehen im Preis und dem Abozeitraum: Mit dem Jahresabo sparst du auf 12 Monate gerechnet im Vergleich zum Monatsabo rund 30 %.
Was ist Perlego?
Wir sind ein Online-Abodienst für Lehrbücher, bei dem du für weniger als den Preis eines einzelnen Buches pro Monat Zugang zu einer ganzen Online-Bibliothek erhältst. Mit über 1 Million Büchern zu über 1.000 verschiedenen Themen haben wir bestimmt alles, was du brauchst! Weitere Informationen hier.
Unterstützt Perlego Text-zu-Sprache?
Achte auf das Symbol zum Vorlesen in deinem nächsten Buch, um zu sehen, ob du es dir auch anhören kannst. Bei diesem Tool wird dir Text laut vorgelesen, wobei der Text beim Vorlesen auch grafisch hervorgehoben wird. Du kannst das Vorlesen jederzeit anhalten, beschleunigen und verlangsamen. Weitere Informationen hier.
Ist Transformer Ageing als Online-PDF/ePub verfügbar?
Ja, du hast Zugang zu Transformer Ageing von Tapan Kumar Saha, Prithwiraj Purkait, Tapan Kumar Saha, Prithwiraj Purkait im PDF- und/oder ePub-Format sowie zu anderen beliebten Büchern aus Scienze fisiche & Energia. Aus unserem Katalog stehen dir über 1 Million Bücher zur Verfügung.

Information

Jahr
2017
ISBN
9781119239987
Auflage
1
Thema
Energia

1
Transformer Insulation Materials and Ageing

1.1 Introduction

The primary and secondary coils of a transformer are the key components in performing its basic function of transforming voltage and current. Materials are used to insulate the primary and secondary coils. In transformers, in addition to the primary and secondary coils, there are several other important components and accessories. The insulating material is one of the most critical components of a transformer. Sufficient insulation between different active parts of the transformer is necessary for its safe operation. Adequate insulation is not only necessary to isolate coils from one another, or from the core and tank, but also ensures the safety of the transformer against accidental over‐voltages.
The insulation system in a transformer can be categorized as follows.
  • Major insulation:
    • – between core and low‐voltage (LV) winding;
    • – between LV and high‐voltage (HV) winding;
    • – between top and bottom of winding and yoke;
    • – between HV and tank;
    • – bushings.
  • Minor insulation:
    • – between conductors;
    • – between turns;
    • – between layers;
    • – between laminations;
    • – between joints and connections.
The insulation material commonly used between the grounded core and the LV coil to ground, and also between HV and LV coils, is oil‐impregnated solid pressboard. Solid insulation, including pressboard or paper, can have small internal air voids. This reduces the insulating strength of the solid insulation as well as reducing its heat dissipation capacity. When transformer oil is used to impregnate solid insulation, the voids are filled with oil, resulting in an improvement of both the insulation strength and the heat dissipation capacity of the solid insulation. In larger transformers, cellulose‐based paper tape is usually wrapped over individual conductors. Layer‐to‐layer or disc‐to‐disc insulation is mostly provided by oil‐impregnated Kraft paper or even thick pressboard or transformer board in case of higher‐rating transformers.

1.2 Solid Insulation – Paper, Pressboard

The solid insulation materials widely used in the transformer are paper, pressboard, and transformer board, which are formed from the cellulose found in plants. Cellulose insulation with mineral oil has played a major role as the main insulation system for transformers for a very long time. Cellulose paper, tapes, and cloths have also been widely used. They provide excellent dielectric strength and low dielectric loss, and hence impregnated paper is now widely accepted as the insulation pillar of the electricity industry. Paper and pressboard insulation derived from pure cellulose have an excellent capacity for being impregnated with oil, thereby improving their insulation properties many times over. In addition, such solid insulating materials are easy to mold and wrap around coils, and can be made of various dimensions as per requirements.
The main concern with using dry paper as an insulating material is that it is very hygroscopic (i.e., it readily absorbs moisture). In order to overcome this deficiency, it must be dried and treated (impregnated) in some liquid (oil, varnish, resins) to reduce moisture ingress and maintain its dielectric strength. Such treatments fill the spaces between fibers and increase the dielectric strength. Nowadays, other synthetic insulating materials are used to insulate areas where the operating temperature is designed to be high (hybrid insulation), or for entire transformers specially designed to operate at high temperatures (artificial polymer – e.g., Aramid paper). Max Schaible summarized several lists of desirable qualities of high‐voltage insulation, as shown in Table 1.1.
Table 1.1 Desirable qualities for electrical grade fibers
Source: Ref. [1].
Natural pulp (wood, cotton, hemp, etc.) Synthetic pulp (polymers)
Chemical properties Chemical properties
  • High cellulose content
  • Low lignin content for reduced specific conductivity
  • Low hemicellulose content for low p.f.
  • Low ash for low inorganic ion content [low ionic impurities; replace mono‐ with bivalent ions (Ca++, Ba++ for Na+), wash with deionized water to reduce dielectric losses]
  • High molecular weight for good mechanical properties
  • Low shieve or knot content
  • Blocked hydroxyl groups to lower the dielectric constant of paper w.r.t. that of oil
  • Low carboxyl number for lower high‐temperature losses
  • Select crosslinking to depolymerizing polymers
  • Select materials with high Tg for thermal stability
  • Optimize mechanical strength through adjustment of molecular weight and molecular distribution
  • Reduce polar group content for better electrical properties
  • Choose chemically inert aromatic polymers with little swelling in oil at service temperatures
  • Avoid adding hydrogen or halogen groups to the carbons next to the carbon with characteristic functional moiety (6)
Physical properties Physical properties
  • High density for good electrical strength
  • Low moisture content after oil impregnation
  • High oil penetration (low density) for low overall dielectric constant
  • High air resistance (beat pulp to optimize conduction through inter‐fiber bonding and mechanical strength)
  • Minimize fiber‐to‐film void content
  • Optimize cross‐sectional shape of fiber for good mechanical strength
  • Maximize bonding between polymer fibers by heat, mechanical entanglement, or chemical means
  • Raise air resistance

1.2.1 Cellulose Structure

Natural cellulose comes from plants. Paper and pressboard insulation is generally made from a “Kraft” process. The typical composition of unbleached softwood Kraft is as follows:
75–85% cellulose
10–20% hemicelluloses
2–6% lignin
<0.5% inorganic
The structures of glucose and cellulose are shown in Figures 1.1 and 1.2.
Image described by caption.
Figure 1.1 Chemical structure of glucose.
Image described by caption.
Figure 1.2 Chemical structure of cellulose (polymer chains of glucose).
Cellulose is a linear polymer of anhydro‐g...