Atomic Emission Spectrometry
eBook - ePub

Atomic Emission Spectrometry

AES - Spark, Arc, Laser Excitation

Heinz-Gerd Joosten, Alfred Golloch, Jörg Flock, Susan Killewald

Compartir libro
  1. 350 páginas
  2. English
  3. ePUB (apto para móviles)
  4. Disponible en iOS y Android
eBook - ePub

Atomic Emission Spectrometry

AES - Spark, Arc, Laser Excitation

Heinz-Gerd Joosten, Alfred Golloch, Jörg Flock, Susan Killewald

Detalles del libro
Vista previa del libro
Índice
Citas

Información del libro

Atomic Emission Spectrometry is a powerful analytical method which is utilized in academia and industry for quantitative and qualitative elemental analysis. This publication is an excellent guide to the technique, explaining the underlying theory and covering practical measurement applications. Extremely well-written and organized, this book is a beneficial instrument for every scientist or professional working with AES.

Preguntas frecuentes

¿Cómo cancelo mi suscripción?
Simplemente, dirígete a la sección ajustes de la cuenta y haz clic en «Cancelar suscripción». Así de sencillo. Después de cancelar tu suscripción, esta permanecerá activa el tiempo restante que hayas pagado. Obtén más información aquí.
¿Cómo descargo los libros?
Por el momento, todos nuestros libros ePub adaptables a dispositivos móviles se pueden descargar a través de la aplicación. La mayor parte de nuestros PDF también se puede descargar y ya estamos trabajando para que el resto también sea descargable. Obtén más información aquí.
¿En qué se diferencian los planes de precios?
Ambos planes te permiten acceder por completo a la biblioteca y a todas las funciones de Perlego. Las únicas diferencias son el precio y el período de suscripción: con el plan anual ahorrarás en torno a un 30 % en comparación con 12 meses de un plan mensual.
¿Qué es Perlego?
Somos un servicio de suscripción de libros de texto en línea que te permite acceder a toda una biblioteca en línea por menos de lo que cuesta un libro al mes. Con más de un millón de libros sobre más de 1000 categorías, ¡tenemos todo lo que necesitas! Obtén más información aquí.
¿Perlego ofrece la función de texto a voz?
Busca el símbolo de lectura en voz alta en tu próximo libro para ver si puedes escucharlo. La herramienta de lectura en voz alta lee el texto en voz alta por ti, resaltando el texto a medida que se lee. Puedes pausarla, acelerarla y ralentizarla. Obtén más información aquí.
¿Es Atomic Emission Spectrometry un PDF/ePUB en línea?
Sí, puedes acceder a Atomic Emission Spectrometry de Heinz-Gerd Joosten, Alfred Golloch, Jörg Flock, Susan Killewald en formato PDF o ePUB, así como a otros libros populares de Physical Sciences y Analytic Chemistry. Tenemos más de un millón de libros disponibles en nuestro catálogo para que explores.

Información

Editorial
De Gruyter
Año
2020
ISBN
9783110527759
Edición
1

1 Introduction

1.1 Definitions

Observation of the interaction of electromagnetic radiation and matter is summarized under the term spectroscopy. In this context, matter consists of atoms, ions, molecules or combinations of such particles, such as metals or liquids. Many of the interactions involve transitions between defined energy states, which are associated with the emission of radiation. Such interactions occur only in the gas phase in free atoms or ions, which led to the terminology atomic emission spectroscopy (AES). The emitted line spectra deliver information about the chemical elements whose atoms or ions are present in the gas phase. Spectroscopy is thus suitable as an analyst’s tool. Spectrometry is a narrowing of the term spectroscopy; it is used when electromagnetic radiation is quantitatively measured.
In addition to the observable spectroscopic effects, there are interactions between radiation and matter, which are not associated with energy transitions. These interactions include refraction, diffraction, reflection and scattering, which change the direction, phase or polarization of radiation [1] (Figure 1.1).
Figure 1.1: Interaction between radiation and matter.
The energy of emitted electromagnetic radiation can be distributed over a large range of frequencies (see Table 1.1). The choice of spectroscopic method determines the frequencies to be used.
Table 1.1:The electromagnetic spectrum.
Wavelength range λ Transition
Gamma radiation <0.005 nm Nucleus
X-rays 0.005–100 nm Inner electrons
Vacuum UV 100–180 nm Valence electrons
Near UV 180–390 nm Valence electrons
Visible region 390–770 nm Valence electrons
Near infrared 770–2,500 nm Valence electrons and molecular vibration
Medium infrared 2.5–50 µm Molecular vibration
Far infrared 50–1.000 µm Molecular rotation
Microwave range 1–1,000 mm Molecular rotation, electron and nuclear spin
Radio wave range >1,000 mm Nuclear spin
The line spectra ranging from 115 nm (vacuum UV) over the visible range (390–770 nm) to approximately 1,000 nm (near infrared) are evaluated in AES, which is the subject of this book.
The atoms and ions present in the gas phase can be excited in a variety of ways. Within the scope of this book, only excitation with electric spark and arc is to be discussed in detail. Excitation by laser sources is only to be marginally addressed.

1.1.1 Spectrometry for material analysis for research and production

The importance of AES is frequently underestimated as a modern method for instrumental analysis. This is difficult to understand when one realizes that 3,000–4,000 mobile and stationary spectrometers are bought and delivered every year. It is estimated that about 50,000 instruments are currently (as of 2017) in use around the world. These figures demonstrate the economic importance of arc/spark AES as an analytical tool.
The manufacture and processing of modern materials depends on competent analytics. The production process for metallic raw materials cannot be controlled without quick monitoring of the melt’s material composition. The precise production of high-quality alloys with defined proportions of alloying elements requires rapid and accurate analysis.
The processing of materials into products leads to good results when continuous quality control is ensured with the help of AES. Efficient machines and components for the aerospace and automotive industries can only be manufactured under these conditions.
Other important application areas for arc/spark AES include the following:
  • Metal identification can be performed with a 100% testing of the composition of the material components.
  • Recycled material can be examined to determine which materials are present. The sorted materials can be reused separately.
  • Basic research on new metallic materials involves a great deal of analytical effort. Experiments for alloy composition can be supported by fast and highly sensitive arc/spark spectrometry.
AES with arc and spark offers many advantages, above all, for material analysis and especially for quality and process control, making it the method of choice [2]:
  • A direct analysis of solid samples is possible without needing to dissolve them.
  • Practically all relevant elements can be simultaneously determined.
  • The measurement proceeds automatically and delivers the result in just a few seconds.
  • Detection sensitivity and reproducibility are good.
  • A wide concentration range, from traces to 100%, can be covered.

1.2 About the history of atomic emission spectrometry

1.2.1 First observations of atomic emission spectra

The first steps of AES, also frequently referred to as “spectral analysis,” began a long time ago [3].
Newton’s observation of the solar spectrum in 1672 was groundbreaking. Representation of this spectrum was performed by blocking a portion of the sunlight using a round hole and then splitting the light with a prism. The spectrum became visible on a white surface behind the prism. However, the spectrum obtained in this way offered only insufficient resolution. Important details became visible only through the use of a narrow entrance slit by Wollaston in 1802. Thin black lines could be seen within the continuous color gradient. The sunlight delivered light throughout the visible range of light, whereby the radiation is missing for various narrowly limited spectral regions. At first, there was no explanation for this phenomenon. Even Fraunhofer [4], who later examined these mysterious black lines, could only measure their positions.
It was only in 1859 after the discoveries from Bunsen and Kirchhoff that it was recognized that the lines could be assigned to chemical elements. Previously, beginning in 1820, the formation of emission spectra in flames was investigated by several researchers, who placed different chemical compounds into the flames [5, 6, 7, 8]. At that time, it was already established that this method could be used to detect the smallest of sample quantities.
At that point, electrical sparks were already being used, in addition to flames, to produce spectra [9, 10, 11, 12]. The spectra from metals as well as compounds were analyzed.

1.2.2 Fundamental work by Bunsen and Kirchhoff dealing with atomic emission spectrometry

In 1859, after a large amount of preliminary work as to the formation of spectra, Bunsen and Kirchhoff explained the basics of spectral analysis in a publication [13]. They discovered that the bright lines in the spectrum of a glowing gas are caused exclusively by its chemical components. They also determined that the chemical binding has no influence on the spectrum. Bunsen and Kirchhoff described the spectra of the alkaline and alkaline earth elements and demonstrated the detection sensitivity of spectral analysis. Using spectr...

Índice