Food Contact Materials Analysis
eBook - ePub

Food Contact Materials Analysis

Mass Spectrometry Techniques

Michele Suman, Michele Suman

Buch teilen
  1. 273 Seiten
  2. English
  3. ePUB (handyfreundlich)
  4. Über iOS und Android verfügbar
eBook - ePub

Food Contact Materials Analysis

Mass Spectrometry Techniques

Michele Suman, Michele Suman

Angaben zum Buch
Buchvorschau
Inhaltsverzeichnis
Quellenangaben

Über dieses Buch

Mass spectrometric techniques have developed over recent years to offer ever increasing solutions to solving problems in food processing and packaging. Even the smallest amount of contamination in food can cause a problem for food production companies, thus they are keen to find speedy and efficient quality control methods.

This book outlines how ingredients and their interrelationship with processing and packaging have developed with the exploitation of mass spectrometry and gives practical protocols to stake holders showing the flexibility of this technique.

With huge relevance worldwide, this book will appeal to food packaging scientists and mass spectrometry practitioners alike.

Häufig gestellte Fragen

Wie kann ich mein Abo kündigen?
Gehe einfach zum Kontobereich in den Einstellungen und klicke auf „Abo kündigen“ – ganz einfach. Nachdem du gekündigt hast, bleibt deine Mitgliedschaft für den verbleibenden Abozeitraum, den du bereits bezahlt hast, aktiv. Mehr Informationen hier.
(Wie) Kann ich Bücher herunterladen?
Derzeit stehen all unsere auf Mobilgeräte reagierenden ePub-Bücher zum Download über die App zur Verfügung. Die meisten unserer PDFs stehen ebenfalls zum Download bereit; wir arbeiten daran, auch die übrigen PDFs zum Download anzubieten, bei denen dies aktuell noch nicht möglich ist. Weitere Informationen hier.
Welcher Unterschied besteht bei den Preisen zwischen den Aboplänen?
Mit beiden Aboplänen erhältst du vollen Zugang zur Bibliothek und allen Funktionen von Perlego. Die einzigen Unterschiede bestehen im Preis und dem Abozeitraum: Mit dem Jahresabo sparst du auf 12 Monate gerechnet im Vergleich zum Monatsabo rund 30 %.
Was ist Perlego?
Wir sind ein Online-Abodienst für Lehrbücher, bei dem du für weniger als den Preis eines einzelnen Buches pro Monat Zugang zu einer ganzen Online-Bibliothek erhältst. Mit über 1 Million Büchern zu über 1.000 verschiedenen Themen haben wir bestimmt alles, was du brauchst! Weitere Informationen hier.
Unterstützt Perlego Text-zu-Sprache?
Achte auf das Symbol zum Vorlesen in deinem nächsten Buch, um zu sehen, ob du es dir auch anhören kannst. Bei diesem Tool wird dir Text laut vorgelesen, wobei der Text beim Vorlesen auch grafisch hervorgehoben wird. Du kannst das Vorlesen jederzeit anhalten, beschleunigen und verlangsamen. Weitere Informationen hier.
Ist Food Contact Materials Analysis als Online-PDF/ePub verfügbar?
Ja, du hast Zugang zu Food Contact Materials Analysis von Michele Suman, Michele Suman im PDF- und/oder ePub-Format sowie zu anderen beliebten Büchern aus Technology & Engineering & Food Science. Aus unserem Katalog stehen dir über 1 Million Bücher zur Verfügung.

Information

CHAPTER 1
Risk Assessment of Plastic-based Food Contact Materials: Focus on Polyolefins
Fabio Testoni*a and Ines Mingozzi*a
a Basell Poliolefine Italia Srl, Italy, R&D PT&C (Process Testing and Characterization), Piazzale Donegani 12, 44122 Ferrara, Italy
*E-mail:[email protected], [email protected]

The aim of this chapter is to describe and comment on analytical approaches for characterizing intentionally added substances (IASs) with specific migration limits (SMLs) and non-intentionally added substances (NIASs) present in polyolefins used in food contact applications. Current EU regulations require the monitoring of packaging material components that could migrate into food, to avoid possible safety and quality issues. Generally, an extraction step involving static headspace (SHS), dynamic headspace and solvent extraction is applied for this purpose. Mass spectrometry coupled with chromatography is the main technique that can provide quantification and identification in line with regulatory requirements. Also, flame ionization detection (FID) is widely used as it allows universal quantitation in many cases. The described techniques can be applied to most of the plastic materials used in food packaging. In this chapter, only polyolefin-based polymers are considered and examples are focused mainly on polypropylene (PP) and its copolymers.

1.1 Introduction

Polyolefins is a term indicating a class of polymers commonly used for, among other applications, food packaging.1 They are produced starting from one or more monomers, polymerization aids (catalysts, peroxides, etc.) and polymer production aids (i.e. in-process antistatic agents). Solvents can also be present. The resulting base polymer is then formulated with additives. Polymers in their final form (generally pellets, granules or flakes) are sold to converters to produce articles.
Monomer(s), additives, polymerization aids (PAs) and polymer production aids (PPAs) are considered intentionally added substances (IASs). Impurities within starting raw materials and reaction products from the manufacturing process (i.e. oligomers, additive by-products) are defined as non-intentionally added substances (NIASs) and are subjected to risk assessment, in addition to PAs and PPAs if not listed in EU or National Food Contact Regulations.
Regulation (EC) No. 1935/2004 of the European Parliament and of the Council of 27 October 2004 provides general principles of safety and inertness for all food contact materials (FCMs). In addition, EU Regulation No. 10/2011 as amended sets out rules for plastic materials in contact with food. EU Regulation No. 10/2011 describes requirements for migration tests. There are two types of limits: OML (overall migration limit) and SML (specific migration limit). OML is based on the total mass of substances that can migrate (gravimetric analysis), whereas SML is based only on quantification of one specific substance that can migrate into food.
EU Regulation No. 10/2011 is based on the principle of a “positive list” and Annex 1 contains the list of authorized chemicals (monomers, additives and certain PPAs). Some listed substances can have an SML. Other substances that are not required to be listed, such as PAs and NIASs, need to be risk assessed.
When a polymer is used for food contact applications, there are important material features that must be considered before approaching any further analytical challenge related to risk assessment:
  1. ODOUR: According to current regulation:2 “… any material or article intended to come into contact directly or indirectly with food must be sufficiently inert to preclude substances from being transferred to food in quantities large enough to endanger human health or to bring about an unacceptable change in the composition of the food or a deterioration in its organoleptic properties.” This means that it is necessary to monitor packaging material components that could migrate into food, deteriorating safety and quality, starting from a low molecular weight.
  2. NIASs: According to EFSA (European Food Safety Association),3 reaction products and impurities (NIASs) that are not included in the EU list of authorized substances in EU Regulation No. 10/2011 are required to be risk assessed, irrespective of their source or intended function. Oligomers are also considered as NIASs. Their identification and quantification are required for risk assessment by Art. 19 of EU Food Contact Regulations 10/2011/EC, specifically for those oligomers with molecular weight (MW) <1000 dalton (Da), as potential migrants of concern which, after transfer (migration) into food, may be physiologically resorbed after ingestion.

1.2 Evaluation of Analytical Approaches

Polymer characterization usually consists of fractionation/extraction or thermal desorption. Fractionation/extraction can be carried out using different solvents and techniques. Aiming to investigate all the species present in an FCM, a combination of analytical methods is used. With polypropylene, a commonly used approach is the separation of the insoluble crystalline part (Xi) from the soluble atactic fraction and oils.4,5 Methylene chloride (CH2Cl2) is another solvent that is commonly used. The fractionated or extracted part can be analysed using different instrumental techniques: NMR (nuclear magnetic resonance), GPC (gel permeation chromatography), GC-FID (gas chromatography coupled with flame ionization detection), GC-MS (gas chromatography coupled with mass spectrometry), HPLC-MS or HPLC-DAD (high-performance liquid chromatography coupled with mass spectrometry or diode-array detection, respectively). The polymer as such can also be thermally desorbed and studied by GC-MS and GC-FID (see Figure 1.1).
image
Figure 1.1Polymer analytical approaches. PP case: fractionation, extraction, thermal desorption. Techniques involved are NMR, GPC and capillary GC.
What emerges is a very complex matrix, with species covering a very wide MW range, starting from a few daltons (residual monomer) up to millions of daltons (high-MW polymers with high crystallinity), as shown in Figure 1.2. This scheme is characteristic and different for each individual polymer.
image
Figure 1.2Scheme of PP polymeric matrix profile, starting from monomer residual, passing through additives and oligomers, arriving at the crystalline fraction. Polymer oligomers are zoomed (circled zone) via GC. The upper scale roughly indicates the region for hydrocarbon clusters; n in parentheses indicates the degree of polymerization when propylene is concerned.
Considering a very common FCM, i.e. a printed film to wrap food, a deeper investigation reveals a very complicated situation (see Figure 1.3). At least four different polymers were used, laminated with a printed surface and glue.
image
Figure 1.3High end use film for food packaging: multi-layer laminated film with printed side and glue.
Analysis of a final item is very difficult and the result is a sum of the contributions from each individual layer component, including the printed layer (with or without paper, when present) and glue, and heating effects during extrusion/lamination. Moreover, it is worth remembering that each film layer can be formed by more than a single polymer.
Very complex matrices, due to different plastic materials and printing and lamination processes, are usually challenging to analyse if the whole production chain is unknown. The final item is analysed to characterize NIASs, but it would often be desirable to obtain more information about the origin of the NIASs.6
For the above reasons, to achieve a full characterization and understa...