Building Drainage
eBook - ePub

Building Drainage

An Integrated Design Guide

Kemi Adeyeye, John Griggs

Partager le livre
  1. 144 pages
  2. English
  3. ePUB (adapté aux mobiles)
  4. Disponible sur iOS et Android
eBook - ePub

Building Drainage

An Integrated Design Guide

Kemi Adeyeye, John Griggs

DĂ©tails du livre
Aperçu du livre
Table des matiĂšres
Citations

À propos de ce livre

Good drainage contributes to the delivery of sustainable, innovative and resilient buildings, and is essential for our health and wellbeing. However, designers and architects can often leave drainage to be implemented by specialists in isolation of other design considerations, resulting in costly changes, rework and repairs, operational discomfort and poor user experiences that could have been avoided. Written for building designers and allied professionals, homeowners and managers as well as the general public, Building Drainage promotes an integrative and collaborative approach. Key principles and components of drainage design are presented in an accessible manner with many UK examples where the underlying information and knowledge can be applied internationally. coverage includes waste and foul water drainage systems and the benefits of integrated water management (IWM) approach, where 'waste' becomes a valuable resource; surface and rainwater drainage; water and energy efficiency through wastewater recycling and reuse, and heat recovery. After reading this book you will understand the mostly invisible, or unperceived, yet vital aspects of functional drainage design and their interaction with the architecture of the building as well as the local and global environments.

Foire aux questions

Comment puis-je résilier mon abonnement ?
Il vous suffit de vous rendre dans la section compte dans paramĂštres et de cliquer sur « RĂ©silier l’abonnement ». C’est aussi simple que cela ! Une fois que vous aurez rĂ©siliĂ© votre abonnement, il restera actif pour le reste de la pĂ©riode pour laquelle vous avez payĂ©. DĂ©couvrez-en plus ici.
Puis-je / comment puis-je télécharger des livres ?
Pour le moment, tous nos livres en format ePub adaptĂ©s aux mobiles peuvent ĂȘtre tĂ©lĂ©chargĂ©s via l’application. La plupart de nos PDF sont Ă©galement disponibles en tĂ©lĂ©chargement et les autres seront tĂ©lĂ©chargeables trĂšs prochainement. DĂ©couvrez-en plus ici.
Quelle est la différence entre les formules tarifaires ?
Les deux abonnements vous donnent un accĂšs complet Ă  la bibliothĂšque et Ă  toutes les fonctionnalitĂ©s de Perlego. Les seules diffĂ©rences sont les tarifs ainsi que la pĂ©riode d’abonnement : avec l’abonnement annuel, vous Ă©conomiserez environ 30 % par rapport Ă  12 mois d’abonnement mensuel.
Qu’est-ce que Perlego ?
Nous sommes un service d’abonnement Ă  des ouvrages universitaires en ligne, oĂč vous pouvez accĂ©der Ă  toute une bibliothĂšque pour un prix infĂ©rieur Ă  celui d’un seul livre par mois. Avec plus d’un million de livres sur plus de 1 000 sujets, nous avons ce qu’il vous faut ! DĂ©couvrez-en plus ici.
Prenez-vous en charge la synthÚse vocale ?
Recherchez le symbole Écouter sur votre prochain livre pour voir si vous pouvez l’écouter. L’outil Écouter lit le texte Ă  haute voix pour vous, en surlignant le passage qui est en cours de lecture. Vous pouvez le mettre sur pause, l’accĂ©lĂ©rer ou le ralentir. DĂ©couvrez-en plus ici.
Est-ce que Building Drainage est un PDF/ePUB en ligne ?
Oui, vous pouvez accĂ©der Ă  Building Drainage par Kemi Adeyeye, John Griggs en format PDF et/ou ePUB ainsi qu’à d’autres livres populaires dans Technology & Engineering et Construction & Architectural Engineering. Nous disposons de plus d’un million d’ouvrages Ă  dĂ©couvrir dans notre catalogue.

Informations

Éditeur
Crowood
Année
2019
ISBN
9781785006401
PART ONE : OUTSIDE THE BUILDING

Chapter 1

WASTEWATER DRAINAGE SYSTEMS

This chapter discusses the evolution of site-based and municipal drainage systems and the importance of good drainage for public health and well-being. It also highlights the importance of good drainage design and the choice of appropriate methods for achieving both water efficiency and resilience. The second part of the chapter will present the main terminology, criteria and factors that inform ‘traditional’ drainage design in and around buildings and the built environment.
Here, building drainage system types and design considerations are discussed with particular focus on the collection and transmission of rainwater, foul and wastewater from buildings; commonly referred to as sewer systems. In the UK, sewer systems can be private and public, or separate and combined.
Useful standards and guidance documents include:
‱BS EN 752 (2017) Drain and sewer systems outside buildings. Sewer system management (formerly seven parts, now only one part)
‱BS EN 12056 Part 3 Gravity drainage systems inside buildings – Roof drainage, layout and calculation (although title is for ‘inside buildings’ the scope includes rainwater drainage attached to a building)
‱EN 16933-2 (2018) Drain and sewer systems outside buildings – Design Part 2: Hydraulic design
‱BS EN 1610 Construction and testing of drains and sewers
‱BS EN 16932-1 (2018) Drain and sewer systems outside buildings. Pumping systems (In 3 parts including Vacuum systems and Positive pressure systems)
‱BS EN 295 (2013) VitriïŹed clay pipe systems for drains and sewers (Currently in seven parts)
‱BS 65 (1991) SpeciïŹcation for vitriïŹed clay pipes, ïŹttings and ducts, flexible mechanical joints for use solely with surface water pipes and ïŹttings
‱BS 4660 (2000) Thermoplastics ancillary ïŹttings of nominal sizes 110 and 160 for below-ground gravity drainage and sewerage
‱CIBSE Guide G (current version): Public Health & Plumbing Engineering.
The EN 752 is a particularly useful reference. It includes a helpful diagram of the various drainage systems that will be found in a typical urban water catchment e.g. river basin. It shows how the different systems are interconnected and can all impact on local water bodies. It differs from previous drain and sewer standards in that environmental issues are foremost and reference is now given to important European directives such as the:
‱EU Urban Wastewater Treatment Directive (91/271/EEC)
‱EU Bathing Waters Directive (2006/7/EC)
‱EU Groundwater Directive (2006/118/EC)
‱EU ShellïŹsh Waters Directive (2006/113/EC), and the
‱EU Floods Directive (2007/60/EC).
Although the design of a drain or sewer system needs to take into account the anticipated loading, EN 752 also now requires the design to be future-proof by making provisions for:
‱increased flows due to new developments;
‱reduced flows due to changes in the development and changes in water use;
‱increased flows resulting from changes to existing developments;
‱reduced hydraulic capacity resulting from increased hydraulic pipeline roughness (e.g. due to deterioration) in the drains or sewers or wear in pumps;
‱reduced hydraulic capacity due to build-up of sediments in sewers.

Private and Public Sewer Systems

Generally, when drains and sewers are given ownership (private or public), this means that they are piped conduits. Although the terms public and private drains and sewers are used around the world, they can have very different practical and legal meanings. Drains and sewers may be installed in the wealthier parts of the towns if treatment facilities have been developed and there are continuous water supplies, but installations in poorer areas may be limited by water supplies, topography and the high densities of population. In areas where pit latrines predominate, sewerage systems are less common. In such situations, a drain may simply be a ditch and to a nearby water body, e.g. a river.
A private sewer system consists of drainage situated within the boundary of private land or property. This means that the land or property owner is responsible for repair and maintenance. A private sewer can serve multiple housing units, e.g. apartments or buildings within the private boundary whose system of drains then combine to single outlet to a public sewer system.
Public or adopted sewers refers to drains and pipelines outside the property boundary. These are maintained by the local authority or municipality. In England and Wales, The Water Industry (Schemes for Adoption of Private Sewers) Regulations 2011 states that with some exceptions, all privately owned sewers and lateral drains (see deïŹnitions) that communicate with or drains to an existing public sewer as at 1 July 2011 will become the responsibility of the sewerage undertaker – normally the water and sewerage company for the area. However, property owners will still be responsible for the sections of pipe between their property/building and the transferred private sewer or lateral drain. This rule also applies to surface water sewers except those that drain to a water body or outlet other than the public sewer (see Fig. 1.1).
Fig. 1.1 Private Sewer Adoption since 2011. (Adapted from: Defra (2011) The Private Sewer Transfer Regulations: Provisional non-statutory guidance on private sewers transfer regulations. Crown Copyright. June 2011)

Separate and Combined Sewer Systems

Drainage systems consist of above and below-ground networks of pipes designed to convey foul, surface and rainwater to the sewers. These are typically situated to run alongside or under road networks. The below-ground drainage systems can be separate or combined.
A separate drainage system involves using one sewer system to remove rainwater collected from the roof and other surfaces to a public sewer network, and another to remove the foul and wastewater to a different public sewer network. BS EN 1085:2007 Wastewater Treatment Vocabulary [deïŹnition 2120] deïŹnes it as two pipelines, one carrying foul wastewater and the other surface water.
A combined system is where both the rain and foul water are removed via the same public sewer network. Historically and pre-1920s in the UK, a combined sewer was more common. However, there are advantages to a separate sewer system that includes: managing rainwater peak flow – reducing the risks of overflows and backflows of the system; reducing treatment loads since surface water is less contaminated than foul water; and reducing the risk of sewage contamination of water bodies. The situation in most other industrialized countries around the world is similar. Some places, such as Washington in the USA, have tried to separate existing combined sewers, but the cost and disruption is very high.
The trend towards separated systems with sewer systems has increased over the last few decades, as there are more concerns over discharges from combined sewer overflows (CSOs) and a general desire to treat foul water separately to stormwater. However, there is less prevalence of separate drainage systems within buildings, where greywater and blackwater could be separated, as the cleansing effect of flushes from WCs (blackwater) helps to minimize the deposits from surfactant using appliances such as sinks, baths and showers.
Fig. 1.2a Combined drainage systems.
Fig. 1.2b Different options for separate drainage systems.
However, although combined systems can be connected together below ground, many systems exist where rainwater and foul water are combined above ground; for instance using hoppers or branch connections.

Other Drainage Systems

The current...

Table des matiĂšres