Applied Technologies in Pulmonary Medicine
eBook - ePub

Applied Technologies in Pulmonary Medicine

A. M. Esquinas

Condividi libro
  1. 270 pagine
  2. English
  3. ePUB (disponibile sull'app)
  4. Disponibile su iOS e Android
eBook - ePub

Applied Technologies in Pulmonary Medicine

A. M. Esquinas

Dettagli del libro
Anteprima del libro
Indice dei contenuti
Citazioni

Informazioni sul libro

This book is based on a selection of the most original articles published in the past year on new technological advances in the diagnosis and treatment of respiratory diseases. The authors of these papers were invited to contribute to this volume with critical reviews of their recent results and a discussion of the clinical implications of these findings. Technical innovations in the treatment of respiratory diseases involve many aspects from basic physics to pathophysiology and clinical experience in pulmonary and critical care medicine. The book therefore covers a broad spectrum of topics including mechanical ventilation, ventilator modes, new pharmacological treatments during ventilation, prevention of ventilator-associated infections, technologies in anesthesiology, pulmonary rehabilitation, telemonitoring in pediatric and neonatal critical care and assistance in chronic respiratory failure. Diagnostic methods such as polysomnography and ultrasound are considered as well as cardiopulmonary resuscitation methods and new options in inhalation therapies. Furthermore, the role of the environment in respiratory health problems is analyzed, and organizational issues in disaster management and intensive care are highlighted. Intended to help clinicians understand the highly technological diagnostic and therapeutic methods available today, this book will be indispensable for anyone caring for children or adults with respiratory problems, both in the ICU and in daily practice.

Domande frequenti

Come faccio ad annullare l'abbonamento?
È semplicissimo: basta accedere alla sezione Account nelle Impostazioni e cliccare su "Annulla abbonamento". Dopo la cancellazione, l'abbonamento rimarrà attivo per il periodo rimanente già pagato. Per maggiori informazioni, clicca qui
È possibile scaricare libri? Se sì, come?
Al momento è possibile scaricare tramite l'app tutti i nostri libri ePub mobile-friendly. Anche la maggior parte dei nostri PDF è scaricabile e stiamo lavorando per rendere disponibile quanto prima il download di tutti gli altri file. Per maggiori informazioni, clicca qui
Che differenza c'è tra i piani?
Entrambi i piani ti danno accesso illimitato alla libreria e a tutte le funzionalità di Perlego. Le uniche differenze sono il prezzo e il periodo di abbonamento: con il piano annuale risparmierai circa il 30% rispetto a 12 rate con quello mensile.
Cos'è Perlego?
Perlego è un servizio di abbonamento a testi accademici, che ti permette di accedere a un'intera libreria online a un prezzo inferiore rispetto a quello che pagheresti per acquistare un singolo libro al mese. Con oltre 1 milione di testi suddivisi in più di 1.000 categorie, troverai sicuramente ciò che fa per te! Per maggiori informazioni, clicca qui.
Perlego supporta la sintesi vocale?
Cerca l'icona Sintesi vocale nel prossimo libro che leggerai per verificare se è possibile riprodurre l'audio. Questo strumento permette di leggere il testo a voce alta, evidenziandolo man mano che la lettura procede. Puoi aumentare o diminuire la velocità della sintesi vocale, oppure sospendere la riproduzione. Per maggiori informazioni, clicca qui.
Applied Technologies in Pulmonary Medicine è disponibile online in formato PDF/ePub?
Sì, puoi accedere a Applied Technologies in Pulmonary Medicine di A. M. Esquinas in formato PDF e/o ePub, così come ad altri libri molto apprezzati nelle sezioni relative a Medicine e Perinatology & Neonatology. Scopri oltre 1 milione di libri disponibili nel nostro catalogo.

Informazioni

Editore
S. Karger
Anno
2010
ISBN
9783805595858
Applied Technologies in Specific Clinical Situations
Technology in Sleep Pulmonary Disorders
Esquinas AM (ed): Applied Technologies in Pulmonary Medicine. Basel, Karger, 2011, pp 46–50
______________________

Thermal Infrared Imaging during Polysomnography: Has the Time Come to Unwire the ‘Wired’ Subjects?

Jayasimha N. Murthya · Ioannis Pavlidisb
aDivisions of Pulmonary, Critical Care and Sleep Medicine, University of Texas Health Science Center, and bDepartment of Computer Science, University of Houston, Houston, Tex., USA
______________________
Abbreviations
ATHEMOS
Automated thermal monitoring system
BCI
Bayesian credible interval
κ (kappa)
Chance-corrected agreement
Pn
Nasal pressure – airflow monitoring device routinely used in polysomnography
REM
Rapid eye movement
RERA
Respiratory effort-related arousals
SDB
Sleep disordered breathing – encompasses a wide variety of disorders characterized by breathing abnormalities during sleep such as obstructive sleep apnea, central sleep apnea, etc.
TIRI
Thermal infrared imaging
Untreated SDB is a very prevalent problem and can cause daytime sleepiness as well as have far-reaching socioeconomic and health-related consequences. A summary of statistics from three pooled studies estimated that 20% of adults with a body mass index between 25 and 28 kg/m2 have SDB based on an apnea-hypopnea index of >5 per hour [1]. Sleepiness is believed to have played a major role in causing disasters such as the Chernobyl and the Three Mile Island tragedies [2] and has been reported to be the most common cause of fatalities associated with motor vehicle accidents [3]. Untreated SDB is also associated with cardiovascular diseases [4].
Diagnosis of sleep apnea typically involves an overnight sleep study with simultaneous monitoring of airflow channels (Pn, oro-nasal thermistor), electrocardiogram, sleep staging by electroencephalography, electro oculography, and chin and leg electromyography in accordance with the Level 1 recommendations of the American Academy of Sleep Medicine [5]. However, conventional polysomnography has the potential to interfere with the ‘usual’ sleep pattern. A sizeable proportion of patients and normal volunteers who have never had a prior sleep study, experience the ‘first night effect’ characterized mainly by a decrease in sleep efficiency, prolongation of sleep-onset time, increase in REM sleep latency and a reduction in the total amount of REM sleep [6]. Additionally, it has been demonstrated that instrumentation during polysomnography affects body position during sleep [7] and thus impacts the diagnosis of SDB, the severity of which can increase during supine sleep. Moreover, bedside manipulation of sensors, in an effort to obtain high-quality data, may further disturb sleep and hinder our ability to obtain a true representation of the patient's usual sleep pattern. Thus, decreasing subject contact with monitoring equipment and testing in the ‘usual’ sleep environment may help counteract polysomnography's interference with sleep and SDB.
American Academy of Sleep Medicine recommends the use of thermistor as the airflow sensor for the diagnosis of apnea and Pn for the diagnosis of hypopnea as well as RERA [5]. While Pn can overestimate pathological events, especially when subjects change from nasal to predominantly oral breathing, the thermistor on the other hand lacks the sensitivity as compared to Pn, to detect subtle flow abnormalities such as hypopnea and RERAs. Non-contact airflow monitoring technology such as TIRI has the capability to monitor airflow during sleep without subject contact. This concept can be extended to include both laboratory-based and home-based sleep studies.

Description of TIRI

The principle of operation of TIRI is close to that of the oro-nasal thermistor in that both these methods sense thermal radiation. However, it is important to note the following differences between the thermistor and TIRI:
(1) TIRI can sense thermal information at a distance (contact-free), while the thermistor needs to be physically placed and tethered to patient's oro-nasal area, in the proximity of the thermal signal.
(2) TIRI acquires thermal information through natural radiation from the source as opposed to the thermistor which acquires thermal information by conduction when placed in the path of airflow. Theoretically, conduction is bidirectional and has an associated measurement error based on where and when the measurements are made. The accuracy also depends on the intensity as well as the magnitude of change in the thermal signal that is being measured. This error can be detrimental to the detection of subtle airflow abnormalities. TIRI, on the other hand, is an array (imaging sensor) and not just a point sensor-like thermistor. Therefore, it can be used to obtain a thermistor-like signal across time by averaging the thermal signal from all the points in the cross-sectional area of the visible nares, as well as provide thermal information over an extended two-dimensional surface. Analysis of signal as an evolving two-dimensional surface across increases the sensitivity of TIRI and may increase its ability to detect subtle airflow-related phenomena.
Thus, on theoretical grounds alone, one would expect TIRI to be considered a ‘virtual thermistor’ to perform at least as good as the oro-nasal thermistor [8]. Despite these inherent advantages of TIRI as compared to the thermistor, the following significant challenges had to be overcome to realize the translation of this technology for airflow monitoring:
(1) Virtual probing: Since there is no physical probe involved in TIRI, a computational method is needed to segment the nostrils in the image, thus creating a ‘virtual’ probe, where the measurement can be performed. The difference in the temperature of inspired and expired air brings about a temporal variation in the thermal signature of the nostrils. This fluctuating thermal signal helps in the differentiation of the nostrils (or mouth, if the subject is mouth-breathing) from the rest of the facial tissue. The nostrils can thus be segmented from the face with the nasal cartilages forming ‘colder’ boundaries around the thermal signal (fig. 1).
(2) Tracking: Because there is no tethering and the subject is free to move, a computational method is needed to track changes in position, so that the virtual probe stays always in place and the accuracy of measurement is preserved. Functional imaging such as TIRI that maps randomly changing thermophysiological function in a non-restrained subject requires a collaborative network of particle filter trackers based on advanced statistics (coalitional tracking [9]) to compensate for subject movement.
Img
Fig. 1. Temporal variance of nostril region in thermal imagery during breathing: (a) inspiration phase, (b) transition phase, (c) expiration phase, and (d) thermal color map. Note the cold boundaries (labeled ‘Boundaries’) of the nasal cartilages that allow the segmentation of nostrils from the rest of the facial tissue.
(3) Signal extraction: Assuming that virtual probing and tracking work well, they create the opportunity for a good measurement, but not the measurement in itself. Since there is no physical transducer that can produce an electronic signal in response to thermal signal, the signal has to be computationally generated. This has been achieved by continuous wavelet transformation on the normalized thermal signal under the assumption that the breathing component is the strongest part of the varying thermal signal.

Integration of TIRI with Polysomnography

The integrated hardware and software system we used in our preliminary study [10] is called ATHEMOS. The thermal signal acquired by the infrared camera and proce...